Wiring – Empire Comfort Systems VFSR-18-3 EN User Manual

Page 18

Advertising
background image

Page 18

18954-2-0107

Thermostats are not approved on vented decorative appliances.

Label all wires prior to disconnection when servicing controls.

Wiring errors can cause improper and dangerous operation. Verify

proper operation after servicing.
16", 18", 24" and 30" Gas Logs (Millivolt) thermopile is self

powered gas valve and does not require 110 volts. See Figure 22

to provide optional wall switch, thermostat, or remote control.

Maximum length of 20 feet of 16 AWG to conductor wires is to

be used with all optional switches.
Use the two leads (black wires) from

ON/OFF switch to attach

optional components.
Check System Operation

Millivolt system and all individual components may be checked

with a millivolt meter 0-1000 MV range.
Remote Receiver -VFSR-(16, 18, 24, 30)

Use the following steps to place the remote receiver adjacent to

the gas valve.
Attention:

1. The remote receiver can not be placed behind the gas valve and

burner assembly.

2. When facing the appliance, the remote receiver must be placed

to the right of the gas valve and burner assembly.

Note: Do not let remote control receiver come in contact with

burner assembly.
On circulating vent-free firebox, install remote control receiver

behind bottom louver.
Refer to remote control installation and operating instructions for

more details on remote control.
750 Millivolt System

When you ignite the pilot, the thermocouple produces millivolts

(electrical current) which energizes the magnet in the gas valve.

After 30 seconds to 1 minute time period you can release the gas

control knob and the pilot will stay ON. Allow your pilot flame to

operate an additional one (1) to two (2) minutes before you turn the

gas control knob from the PILOT position to the ON position. This

time period allows the millivolts (electrical current) to buildup to a

sufficient level allowing the gas control to operate properly.
Millivolt Control

The valve regulator controls the burner pressure which should be

checked at the pressure test point. Turn captured screw counter

clockwise 2 or 3 turns and then place tubing to pressure gauge over

test point (Use test point “A” closest to control knob). After taking

pressure reading, be sure and turn captured screw clockwise firmly

to re-seal. Do not over torque. Check for gas leaks.
VFSR

Note: (Wiring harness located in envelope)

Connect the 2 - 1/4" terminals onto the TH and TH/TP terminals

on valve. Place decorative log or switch bracket (switch bracket is

used with Flame Art log sets) to

right of the gas valve and burner

assembly. When connecting to remote receiver, cut off 1/4" terminals

from wires attached to ON/OFF switch. Strip wires back about

1/4". Connect stripped ends into remote receiver.

VFSR Wiring Diagram (Figure 22)

Figure 22

VFSV Wiring Diagram (Figure 23)

Figure 23

VFSV

Note: (Wiring harness located in envelope)

Connect black/red 3/16" terminal wire from receiver to 3/16"

terminal on valve. Connect black 1/4" terminal wire from receiver

to 1/4" terminal on valve. Install remote receiver cover over

receiver when receiver is installed into fireplace area. Locate

receiver and cover to the right and forward of valve. (Do not put

receiver behind logs)