18954-2-0107

Attention: During initial use of log you will detect an odor as the log

is cured.
Notice:
During initial firing of this unit, its paint will bake out, and smoke

will occur. To prevent triggering of smoke alarms, ventilate the room in

which the unit is installed.

WARNING: This appliance is for installation only in a solid-fuel

burning masonry or UL 127 factory-built fireplace or in a listed

ventless firebox enclosure. It has been design certified for these

installations. Exception: DO NOT install this appliance in a factory-

built fireplace that includes instructions stating it has not been tested

or should not be used with unvented gas logs.
WARNING: Any modification to this unvented gas heater or its

controls can be dangerous. Improper installation or use of the

heater can cause serious injury or death from fire, burns, explosion

or carbon monoxide poisoning.

Well Head Gas Installations

Some natural gas utilities use "well head" gas. This may affect the Btu output

of the unit. Contact the gas company for the heating value. Contact the

manufacturer or your gas company before changing spud/orifice size.

IMPORTANT: Read all instructions carefully before starting

installation. Failure to follow these installation instructions may result

in a possible fire hazard and will void the warranty.
Save this manual for future reference.
Please read this manual before installing and using the appliance.
Instructions to Installer

1. Installer must leave instruction manual with owner after installation.

2. Installer must have owner fill out and mail warranty card supplied with

unvented room heater/vented decorative appliance.

3. Installer should show owner how to start and operate unvented room

heater/vented decorative appliance.

Always consult your local Building Department regarding regulations,

codes or ordinances which apply to the installation of an unvented room

heater/vented decorative appliance.
This appliance may be installed in an aftermarket* manufactured (mobile)

home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the

manufacturer.

This appliance is only for use with the type of gas indicated on the rating

plate. This appliance is not convertible for use with other gases.
New Installation

VFSV Model - variable does not operate-ON is OFF/OFF is ON-wires

into the back of receiver are reversed.
Solid-fuels shall not be burned in a fireplace where a vented decorative

appliance is installed.
A vented decorative appliance must be installed only in a solid-fuel

burning fireplace with a working flue and constructed of non-combustible

material.
Any alteration of the original design, installed other than as shown in

these instructions or use with a type of gas not shown on the rating plate

is the responsibility of the person and company making the change.
Important

All correspondence should refer to complete Model Number, Serial Number

and type of gas.

BTUH

BTUH

BTUH

Model

Gas

Valve Type

Max. Rate

Med. Rate

Min. Rate

VFSV-16

Natural

Variable

25,000

17,500

VFSV-16

Propane

Variable

22,500

15,750

VFSR-16

Natural

Millivolt

25,000

17,500

VFSR-16

Propane

Millivolt

22,500

15,750

VFSV-18

Natural

Variable

32,000

19,000

VFSV-18

Propane

Variable

32,000

19,000

VFSR-18

Natural

Millivolt

32,000

22,000

VFSR-18

Propane

Millivolt

32,000

22,000

VFSM-18

Natural

Manual

32,000

27,000

22,000

VFSM-18

Propane

Manual

32,000

27,000

22,000

VFSV-24

Natural

Variable

36,000

20,000

VFSV-24

Propane

Variable

36,000

20,000

VFSR-24

Natural

Millivolt

36,000

25,000

VFSR-24

Propane

Millivolt

36,000

25,000

VFSM-24

Natural

Manual

36,000

27,000

22,000

VFSM-24

Propane

Manual

36,000

27,000

22,000

VFSV-30

Natural

Variable

38,000

20,000

VFSV-30

Propane

Variable

38,000

20,000

VFSR-30

Natural

Millivolt

38,000

26,000

VFSR-30

Propane

Millivolt

38,000

26,000

VFSM-30

Natural

Manual

38,000

27,000

22,000

VFSM-30

Propane

Manual

38,000

27,000

22,000

PRODUCT SPECIFICATION

ACCESSORIES

Description

Color

For use with VFSV, VFSM and VFSR models
EK-1

Embers Kit

ELH-1

Fireplace Hood for Vent-Free Logs

Black

ELH-2

Fireplace Hood for Vent-Free Logs

Brass

For use with VFSR models only
FRBC

Battery Operated Remote Control

FRBTC

Battery Operated Remote Control with Thermostat

FREC

Electric Remote Control

FWS

Wall Switch

TMV

Wall Thermostat, Millivolt - Reed Switch

INTRODUCTION

Natural Gas

Propane Gas

Variable

Millivolt

Manual

Variable

Millivolt

Manual

Regulator pressure setting

3.5" W.C.

3.5" W.C. 6.0" W.C.

10.0" W.C.

10.0" W.C.

10.0" W.C.

Gas inlet pressure

Max.

10.5" W.C.

10.5" W.C. 10.5" W.C.

13.0" W.C.

13.0" W.C.

13.0" W.C.

Min.

5.0" W.C.

5.0" W.C. 7.0" W.C.

11.0" W.C.