Combustible material fireplace preparation – Empire Comfort Systems VFSR-18-3 EN User Manual

Page 9

Advertising
background image

Page 9

18954-2-0107

FOR MASONRY BUILT FIREPLACES

FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING

COMBUSTION PRODUCTS FROM DECORATIVE APPPLIANCES

FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES

• Turn off gas supply to fireplace or firebox.

• Have the fireplace floor and chimney professionally cleaned to remove

ashes, soot, creosote or other obstructions.

Have this cleaning performed annually after installation.

• Seal any fresh air vents or ash clean-out doors located on floor or wall

of fireplace. If not, drafting may cause pilot

outage or sooting. Use a heat-resistant sealant. Do not seal chimney

flue damper.

Install and operate the appliance as directed in this manual.

FOR FACTORY BUILT FIREPLACES

FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING

COMBUSTION PRODUCTS FROM DECORATIVE APPLIANCES

FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES

Do not attach combustible material to the mantel of your fireplace. This

is a fire hazard.

Figure 7

No greeting card, stockings or ornamentation of any type should be placed
on or attached to the fireplace. This is a heating appliance. The flow of
heat can ignite combustibles.

Figure 8

COMBUSTIBLE MATERIAL

FIREPLACE PREPARATION

Appliance Input Rate (BTU/hr)

20

30

40

Chimney

Height* (ft)

Minimum Opening** (sq. in.)

10

11.3

16.6

22.1

15

8.6

12.6

17.3

20

7.5

10.8

14.5

25

6.6

9.6

12.6

30

6.2

9.1

11.3

35

5.7

8.0

10.8

40

5.3

7.5

10.2

* Height is from hearth to top of chimney and the minimum height is

10 feet.

** Chart shows minimum opening (sq. in.) for given height and input

rate.

Appliance Input Rate (BTU/hr)

20

30

40

Chimney

Height* (ft)

Minimum Opening** (sq. in.)

6

17.6

25.7

33.8

8

16.5

23.7

31.2

10

15.1

21.7

28.7

15

14.1

19.9

26.1

20

12.9

18.5

23.7

30

12.2

16.9

21.6

* Height is from hearth to top of chimney and the minimum height is

6 feet.

** Chart shows minimum opening (sq. in.) for given height and input

rate.

Advertising