SAF OPAL Pro MS6 User Manual

Page 29

Advertising
background image

MS6 REDUCED VOLTAGE STARTER

Page 28

9 SPARES

9.1 SPARE PARTS

Model

SCR

Current

Transformer

Control

Card

Stack ID

Card

MOV

MS6-30

N10SP03(61A SCR)

T261123 (1500:1)

CA530

CA532(30)

O210050

MS6-50

N10SP06(90A SCR)

T261123 (1500:1)

CA530

CA532(50)

O210050

MS6-80

N10SP16(140A SCR)

T262320 (2500:1)

CA530

CA532(80)

O210050

MS6-125

N728352(300A SCR)

T262320 (2500:1)

CA530

CA532(125) O210050

MS6-250

N728452(580A SCR)

T262320 (2500:1)

CA530

CA532(250) O210050

MS6-420

N718602(720A SCR)

T265320 (5000:1)

CA530

CA532(420) O210050

MS6-500

N718133(1100A SCR)

T268320 (8500:1)

CA530

CA532(500) O210050

MS6-600

N718153(1200A SCR)

T268320 (8500:1)

CA530

CA532(600) O210050

MS6-800

N718552(1500A SCR)

T261321 (10000:1)

CA530

CA532(800) O210050

9.2 SCR INSTALLATION PROCEDURE

• Clean both heat sink and SCR surfaces.
• Apply a thin layer of joint compound (Noalox) to both SCR surfaces.
• Observe correct SCR polarity.
• Install SCR so that roll pins engage dimples on both sides of the SCR.
• Tighten clamp bolts evenly until finger-tight.
• Tighten each bolt according to table below (based on number of spring bars and size of

bars).

Note: SMALL clamps are 10.5cm(4.25inches) and LARGE clamps are 12.5cm(5inches)

CLAMP SIZE

SPRING BARS BOLT TURNS PAST

FINGER TIGHT

SMALL 1

0.75

SMALL 2

1

LARGE 3

1.75

LARGE 4

1.75

Advertising
This manual is related to the following products: