1

I. FURNACE SPECIFICATIONS (SHIPPED SETTINGS)

CHX1 SERIES

MODEL NO.

CHX1-75

CHX1-100

CHX1-125

HEAT INPUT RATE IN BTU/HR
(High fire/ Low fire)

75,000 / 52,000

100,000 / 70,000

125,000 / 87,500

HEATING CAPACITY IN BTU/HR
(High fire/ Low fire)

70,875 / 49,612

94,500 / 66,150

117,500 / 82,250

HEIGHT OF CASING

44-1/4” 44-1/4” 44-1/4”

WIDTH OF CASING

17” 21” 24”

DEPTH OF CASING

27-1/2” 27-1/2” 27-1/2”

WARM AIR OUTLET

15 x 18

19 x 18

22 x 18

RETURN AIR INLET

25 x 16

25 x 16

25 x 16

DIA. OF FLUE

2” 3” 3”

DIA. OF COMBUSTION
AIR INTAKE

2” 3” 3”

FLOWRATE from .2” & .5” w.c.
EXTERNAL STATIC PRESSURE

COOLING COOLING COOLING

@COOLING TAP A (CFM)

1000 1200 1400

@COOLING TAP B (CFM)

800 1000 1200

@COOLING TAP C (CFM)

1200 1400 1600

@COOLING TAP D (CFM)

1400 1600 2000

HEATING HEATING HEATING

@HEATING TAP A
(CFM @High fire/Low fire)

931 / 760

1243 / 1015

1556 / 1270

TEMPERATURE RISE (°F)

70 / 60

70 / 60

70 / 60

BLOWER MOTOR HP

.5 .75 1

POWER CHOKES

-

2.65 Mh

2.1 Mh

LARGEST RECOMMENDED
AIR CONDITIONER

3.5 Ton

4 Ton

5 Ton

SIZE OF FILTERS

24-3/4” x 15-3/4”

24-3/4” x 15-3/4”

24-3/4” x 19-3/4”

NOTES:
1. Heating capacity based on annual fuel utilization efficiency rated by manufacturer.
2. On all outlet and inlet dimensions, the first dimension is width.
3. To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is

required.

4. Electrical characteristics at 115 volts, 60 Hz., 1 phase (less than 15 amps, for all models).
5. All specifications are subject to change without notice.








Advertising