All installations and services must be performed by qualified service personnel.

4

B. CFM TABLES

The following tables contain blower speed settings and their respective air flowrates for the ECM blower motor. To
change air flowrates from that of the shipped settings, use the respective S3 and S4 dipswitches on the furnace’s
integrated control board (see Figure 1).

Dip

switch

settings Low fire CFM Rise (

o

F)

High Fire

CFM

Rise (

o

F)

Dip

switch

settings Low fire CFM

Rise (

o

F)

High Fire

CFM

Rise (

o

F)

7-OFF
8-OFF

760

64

931

70

7-OFF
8-OFF

760

60

931

70

7-ON
8-OFF

708

69

867

75

7-ON
8-OFF

708

65

867

75

7-OFF
8-ON

826

59

1012

65

7-OFF
8-ON

826

55

1012

65

7-ON
8-ON

909

54

1114

59

7-ON
8-ON

909

50

1114

59

Dip

switch

settings Low fire CFM Rise (

o

F)

High Fire

CFM

Rise (

o

F)

Dip

switch

settings Low fire CFM

Rise (

o

F)

High Fire

CFM

Rise (

o

F)

7-OFF
8-OFF

1015

64

1243

70

7-OFF
8-OFF

1015

60

1243

70

7-ON
8-OFF

947

69

1160

75

7-ON
8-OFF

947

64

1160

75

7-OFF
8-ON

1094

60

1340

65

7-OFF
8-ON

1094

56

1340

65

7-ON
8-ON

1184

55

1450

60

7-ON
8-ON

1184

51

1450

60

Dip

switch

settings Low fire CFM Rise (

o

F)

High Fire

CFM

Rise (

o

F)

Dip

switch

settings Low fire CFM

Rise (

o

F)

High Fire

CFM

Rise (

o

F)

7-OFF
8-OFF

1270

64

1556

70

7-OFF
8-OFF

1270

60

1556

70

7-ON
8-OFF

1185

69

1452

75

7-ON
8-OFF

1185

64

1452

75

7-OFF
8-ON

1366

60

1673

65

7-OFF
8-ON

1366

56

1673

65

7-ON
8-ON

1480

55

1813

60

7-ON
8-ON

1480

51

1813

60

=FACTORY SHIPPED SETTINGS

CDX1-125

CHX1-125

HEATING SPEEDS

CDX1-75

CHX1-75

CDX1-100

CHX1-100