Thermo Pride Gas/Propane Furnace ECM CHX1 User Manual

Page 7

Advertising
background image

All installations and services must be performed by qualified service personnel.

5



Dip

switch

setting

Continuous

fan

CFM

Cooling CFM

Dip

switch

setting

Continuous

fan

CFM

Cooling CFM

Dip

switch

setting

Continuous

fan

CFM

Cooling CFM

1-OFF
2-OFF
3-ON
4-OFF

500

1150

1-OFF
2-OFF
3-ON
4-OFF

600

1380

1-OFF
2-OFF
3-ON
4-OFF

700

1610

1-OFF
2-OFF
3-OFF
4-OFF

500

1000

1-OFF
2-OFF
3-OFF
4-OFF

600

1200

1-OFF
2-OFF
3-OFF
4-OFF

700

1400

1-OFF
2-OFF
3-OFF
4-ON

500

850

1-OFF
2-OFF
3-OFF
4-ON

600

1020

1-OFF
2-OFF
3-OFF
4-ON

700

1190

1-ON
2-OFF
3-ON
4-OFF

400

920

1-ON
2-OFF
3-ON
4-OFF

500

1150

1-ON
2-OFF
3-ON
4-OFF

600

1380

1-ON
2-OFF
3-OFF
4-OFF

400

800

1-ON
2-OFF
3-OFF
4-OFF

500

1000

1-ON
2-OFF
3-OFF
4-OFF

600

1200

1-ON
2-OFF
3-OFF
4-ON

400

680

1-ON
2-OFF
3-OFF
4-ON

500

850

1-ON
2-OFF
3-OFF
4-ON

600

1020

1-OFF
2-ON
3-ON
4-OFF

600

1380

1-OFF
2-ON
3-ON
4-OFF

700

1610

1-OFF
2-ON
3-ON
4-OFF

800

1840

1-OFF
2-ON
3-OFF
4-OFF

600

1200

1-OFF
2-ON
3-OFF
4-OFF

700

1400

1-OFF
2-ON
3-OFF
4-OFF

800

1600

1-OFF
2-ON
3-OFF
4-ON

600

1020

1-OFF
2-ON
3-OFF
4-ON

700

1190

1-OFF
2-ON
3-OFF
4-ON

800

1360

1-ON
2-ON
3-ON
4-OFF

700

1600

1-ON
2-ON
3-ON
4-OFF

800

1700

1-ON
2-ON
3-ON
4-OFF

1000

2300

1-ON
2-ON
3-OFF
4-OFF

700

1400

1-ON
2-ON
3-OFF
4-OFF

800

1600

1-ON
2-ON
3-OFF
4-OFF

1000

2000

1-ON
2-ON
3-OFF
4-ON

700

1190

1-ON
2-ON
3-OFF
4-ON

800

1360

1-ON
2-ON
3-OFF
4-ON

1000

1700

COOLING AND CONTINUOUS FAN SPEEDS

CDX1-125 & CHX1-125

=FACTORY SHIPPED SETTINGS

CDX1-75 & CHX1-75

CDX1-100 & CHX1-100