Table 2-1. front panel lockout commands, 3 digital control via lan [e-series models only, Digital control via lan [e-series models only] -2 – KEPCO KLR Series Developers Guide User Manual

Page 20: Front panel lockout commands -2

Advertising
background image

2-2

KLR-DEV 060713

2.3

DIGITAL CONTROL VIA LAN [E-SERIES MODELS ONLY]

Figure 2-1 shows all the ports available to the LAN interface. These port are described in Sec-
tion 9, LAN INTERFACE [E-Series MODELS ONLY], and include:

• Port 80 - Web Interface. (See KLR User Manual for details on how to use the web inter-

face.) This port supports up to eight connections. For details as to how to access, oper-
ate and configure the unit using the web interface, refer to the KLR User Manual. In
addition, the web interface is compatible with \\LXI\instrument.xml and
\\LXI\instrument.xsd required by Version 1.2 of the LXI specification.

• Port 111 - SUNRPC (UDP Broadcast and TCP/IP). The SUNRPC port is used for discov-

ery when sent as a UDP broadcast message. The only command supported is the GET-
PORT. The ports that can be requested are detailed in the VXI specification and
repeated in the LXI specifications. The SUNRPC port can be also used with the TCP/IP
protocol. Again, the only command supported is the GETPORT. Port 111 is the method
(called the Discovery process) used by National Instruments and Agilent to find the
resource. KLR E-Series Models support the discovery process implemented by Version
1.1 of the LXI Specification using this port and a VXI-11 protocol, as well as the XML pro-
tocol proposed by Version 1.2 of the LXI specification.

• Port 1024 - VXI-11. This port supports up

to

two

connections.

VXI-11 uses one stan-

dard port (1024) and two assigned by the instrument when connections are opened. The
1024 port is open at all times to accept connection requests. The VXI-11 port requires
the use of a lock which prevents other VXI-11 connections from gaining access to the
instrument. This port is accessed using the VISA resource string ending in INST, e.g.:

TCIP0::192.168.1.100::INST

• Port 5024 - Telnet. This port supports up to two connections. the Telnet command pro-

vided with all windows operating systems can be run with the following command line
(use Start - Run) TELENET IPADDRESS PORT e.g.:

TELNET 192.168.0.100 5024

When the program is run, entering commands found in Appendix A and B of this Devel-
oper’s Guide allow the operation of the unit via the Telnet port.

TABLE 2-1. FRONT PANEL LOCKOUT COMMANDS

Environment

Command

Description

Programming

SYSTem:KLOCk

Follow with on or off. Setting on locks the front panel.

VXI plug&play

Kp_KLR_SetResetKeyblock

Requires the instrument session and a Boolean value of 0 for off and 1
to lock the keyboard.

LabView G

Kepco Serial initialize with options

The input defaults to lock the keyboard.

IVI-COM

Requires the instrument session and a Boolean value of 0 for off and 1
to lock the keyboard.

Advertising