0 introduction, 1 scope of manual, 2 description – KEPCO RCW 1500W Series User Manual

Page 3: 0 specifications, Table 1. power supply ratings and specifications, Scope of manual, Description, Specifications

Advertising
background image

RCW 1500W 120607

1

1.0 INTRODUCTION

1.1 SCOPE OF MANUAL

This Operator's Manual covers the installation and operation of the Kepco RCW 1500W Series of

Switching Power Supplies. For service information, write directly to: Kepco Inc., 131-38 Sanford

Avenue, Flushing, New York, 11355, U.S.A. Please state Model Designation and Serial Number of

your RCW Power Supply. This information can be found on the nameplate of the unit.

1.2 DESCRIPTION

The Kepco RCW 1500W Series consists of seven models of Switching Power Supplies, with a sin-

gle output as shown in Table 1. RCW power supplies are compliant with the Low Voltage Directive

(LVD) and carry the CE Mark. Units are designed to operate with a universal input voltage within the

range of 85 to 264V AC and may be operated with either 100-120V AC, or 200-240V AC, 50-60 Hz

(47-66 Hz) input. They will also operate on 125V to 370V dc input. The RCW 1500W Series

employs a light weight ferrite core transformer with 150 KHz typical switching frequency. The

Power Factor Correction Circuit has a typical switching of 80 KHz. Regulation is provided by pulse

width modulation. A FET power stage, operating in the forward conversion mode provides a

smooth isolated dc output. A resistor and thyristor "soft-start" circuit prevents excessive turn-on

current surge. Overvoltage protection and optically isolated remote TTL ON-OFF control are pro-

vided. Current limiting with automatic recovery from short circuit is featured. Units are enclosed in a

wrap-around aluminum case with a green LED "output present" light visible on the terminal side of

the case.

2.0 SPECIFICATIONS

Table 1 contains specifications and operating limits of individual RCW 1500W Series models. Table

2 contains specifications and operating limits common to all RCW 1500W Series Models. These

specifications are at nominal input voltages at 25°C unless otherwise specified.

TABLE 1. POWER SUPPLY RATINGS AND SPECIFICATIONS

MODEL RCW 1500W

3.3-300K

5-300K

12-125K

15-100K

24-65K

28-55K

48-32K

Output Volts d-c

(5)

3.3V

5V

12V

15V

24V

28V

48V

Adjustment Range

(7)

1.8-3.5

3.5~5.5

8.4~13.2

12.0~16.5

16.5~26.4

25.2~30.8

30.8~52.8

Maximum

Output

Ratings

(Amps/

Watts

50°C, amb A

300

300

125

100

65

55

32

50°C, amb W

1050

1500

1500

1500

1560

1540

1536

60°C, amb A

210

210

87.5

70A

45.5

38.5

22.4

60°C, amb W

735

1050

1050

1050

1092

1078

1075.2

70°C, amb A

120

120

50

40

26

22

12.8

70°C, amb W

420

600

600

600

624

616

614.4

Current Limit (Amps)

(1)

315-350

315-350

130-140

105-115

68-72

57.7-63.2

33.6-36.8

OVP Settings (Volts)

(2)

3.96-4.62

6.0-7.0

13.2-15.6

16.5-19.5

26.4-31.2

30.8-36.4

49.44-59.04

Efficiency %

typical

AC Input 120V

70

75

76

76

78

79

80

AC Input 240V

73

80

81

81

82

83

84

Ripple &

Noise

(3)

(mV, p-p)

output ripple (max)

100

100

100

100

100

100

100

spike noise (max)

(4)

200

200

200

200

200

200

300

Transient
Recovery

(6)

Recovery to

1%(<ms)

1

1

1

1

1

1

1

Excursion ±V max

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1)

The Power Supply has a square type overcurrent characteristic, shutdown by undervoltage detection

2)

The Power Supply has a shut-down type (by tracking) overvoltage characteristic. Recovery time to reset 40 seconds minimum

3)

Source component 2x source frequency and switching component approximately 150 KHz, 10 to 100% load and ambient Ta = 25°C

4)

Measure with a 50MHz bandwidth, 10 to 100% load and ambient Tc= 25°C

5)

Output voltage setting = ±1%

6)

A step load change from 50% to 100% of rated load current (with the following tr, tf load changes) produces no more than the output

voltage excursions listed in the above table. The load change will be 5A/µs for Io>20A and 1A/µs for I<20A tr, tf of load change

:

3.3v and

5v>30µs, 12v>12.5µs, 15v>10µs, 24v>6.5µs, 28v>5.5µs, 48v>3.2µs,

7)

Recommended (using internal adjustment pot, par. 3.4). Using external pot (par.3.5) range = 10% to 110% of rated output voltage.

Advertising