Installation Instructions

Rating 50,000 lbs. (22,680kg) (Figure 4)
Use two (2) 5/8" Grade 8 bolts with
supplied hardened clipped washers (clipped
edge facing down) in lower holes. Torque
5/8" bolts (clean and dry) to 180 ft.-lbs.
(245 N•m) minimum. Use two (2) 1/2"
Grade 8 bolts with supplied hardened flat
washers in upper holes. Torque 1/2" bolts
(clean and dry) to 100 ft.-lbs. (135 N•m)
minimum. Nuts used must be ASTM grade
“C” or better.

This hole pattern will match the
following products:

• HOLLAND: EH-40RP Series E-Hitches

Failure to use supplied
washers or proper bolts
when mounting could
result in unexpected
E-Hitch failure, which if
not avoided could result
in death or serious injury.

3.50

(88.9)

3.50

(88.9)

Figure 4

1/2" GR. 8
BOLTS

1/2" WASHER

50,000 LB. (22,680KG) D.B.P.

5/8" GR. 8
BOLTS

5/8"
WASHER