8

LED INDICATORS

8 . 1

E t h e r n e t

The LEDs on the Ethernet connector indicate the Ethernet connection and activity status.

Left Link LED

Status

Right Activity LED

Status

Amber color

10 Mbps

Amber color

Half duplex

Green color

100 Mbps

Green color

Full duplex

On

Link established

On/flashing

Data activity

Off

No link

Off

No activity

8 . 2

U - N e t I n d i c a t o r s

The U-Net LEDs on the front/rear panels indicate the U-Net network status.

Green LED ( )

Red/Yellow LEDs (!) Status

On

Off

U-Net network detected

On

Flashing

Local fault: not sending or receiving on the assigned
U-Net channel(s) or local and received sample rates are
not synchronized

On

On (2 seconds)

Local fault detected on another device on the network

Off

Off

No network detected

8 . 3

I n p u t m e t e r s

The input meters indicate the signal level in dB below 0 dBFS (0 dB Full Scale), the clip level of the ADC
(analog to digital converter). An input meter still functions when its Input Channel is muted. Ideally, the
highest levels of the signal should illuminate the -6 LED segment, but not the CLIP segment. Occasional
flashing of the CLIP segment may be sonically acceptable.

LED Segment

Signal Level

Clip Red

0 dBFS

- 6 Yellow

-6 dBFS

-12 Green

-12 dBFS

Sig Green

-40 dBFS

8 . 4

O u t p u t M e t e r s

Unlike the input meters, the four LED segments of each output meter make up two different meters.

8.4.1

SIG, -12, AND CLIP SIG SEGMENTS

These three segments monitor the signal level in dB below 0 dBFS (0 dB Full Scale), the clip level of the
DAC (digital to analog converter). An output meter still functions when its Output Channel is muted.
Ideally, you want the highest level to illuminate the -12 segment, but not the CLIP segment. You can set
levels lower than this, but understand that you are reducing the signal-to-noise ratio.

LED Segment

Signal Level

Clip Red

0 dBFS

-12 Green

-12 dBFS

Sig Green

-40 dBFS

8.4.2

LIM SEGMENT

This segment monitors the limiter status referenced to the level set for the limiter threshold. The Lim
segment will indicate limiting even when its Output Channel is muted.

LED Segment

Status

Lim Yellow

On when the limiter threshold is exceeded and there is gain reduction

Occasional flashing is OK. However, if the LED is rapidly flashing yellow or is on steadily a large
percentage of the time, the input signal to the loudspeaker may be exceeding the loudspeaker’s capability
and the volume level should be reduced.

Page 20

OUTPUT CHANNELS

OUTPUT CHANNELS

Clip

Clip

Lim

-12

-12

Sig

Sig

Clip

Clip

Lim

Lim

-12

-12

Sig

Sig

Clip

Clip

Lim

Lim

-12

-12

Sig

Sig

Clip

Clip

Lim

Lim

-12

-12

Sig

Sig

Clip

Clip

Lim

Lim

-12

-12

Sig

Sig

2

3

4

5

6

ETHERNET

ETHERNET

2

1

U-NET

U-NET

U-NET

1

2

INPUT CHANNELS

INPUT CHANNELS

Clip

Clip

-6

-6

-12

-12

Sig

Sig

Clip

Clip

-6

-6

-12

-12

Sig

Sig

Clip

Clip

-6

-6

-12

-12

Sig

Sig

Clip

Clip

-6

-6

-12

-12

Sig

Sig

A

B

C

D

Advertising