Elation Professional PLATINUM BEAM 5R XM485-V1.0-NR User Manual

Page 17

Advertising
background image

15

Lamp Control:

Lamp On or Off

This function allows manual control of the lamp power via the on-board system

menu.

• Select “ON” if you wish to strike the lamp or “OFF” to switch it off.

• Press “ENTER” to confirm.

• Press the Mode/Esc-button to return to the main menu.

Automatic La-On

When in the “ON” position, this function will automatically turn the lamp on when

power is applied to the fixture

Lamp On Via DMX

When engaged, this function will allow the lamp to be switched “on” via a DMX

controller. Select “ON” to enable this function or “OFF” to disable it.

Lamp Off Via DMX

When engaged, this function will allow the lamp to be switched “off” via a DMX

controller. Select “ON” to enable this function or “OFF” to disable it.

Lamp On at Temp.

The fixture is designed to shut the lamp off when an excessive temperature is

sensed inside the head by the on-board CPU. The lamp is shut down to prevent

damage to the lamp and avoids possible internal damage to the head. This function

sets the minimum temperature for lamp restrike after the lamp has been

automatically shut off.

Lamp Off at Temp.

The fixture is designed to shut the lamp off when an excessive temperature is

sensed inside the head by the on-board CPU. The lamp is shut down to prevent

damage to the lamp and avoids possible internal damage to the head. This function

sets the maximum internal operating temperature of the head before the lamp will

automatically be shut down. This function can be set to activate at an internal

temperature between 80° C and 139° C. Inside temperatures below 90° C are not

critical. Temperatures above 90° C should lead to the lamp being switched off.

Please note that the outside temperature should not exceed 45° C.

XM485-V1.0-NR

Advertising