3.11 Internal Pull-Ups and Pull-Downs

Table 3.23

describes the pull-up and pull-down signals for the

LSI53C1030.

Table 3.23

Pull-Up and Pull-Down Conditions

Signal Name

BGA Position

Pull Type

MAD[15:0], MADP[1:0]

D22, E21, B25, D23, E22, C24,
F22, E23, D26, E25, H22, F24,
G23, D25, F23, G22, C22, B24

Internal Pull-down.

SerialDATA, SerialCLK

H26, J25

Internal Pull-down. Pull-up
externally when connected
to a serial EEPROM.

GPIO[7:0]

K25, L23, L25, M25, H25, K24,
AE25, AC23

Internal Pull-down.

TST_RST/

AD5

Internal Pull-up.

TCK_CHIP, TDI_CHIP, TMS_CHIP AC6, AF3, AE4

Internal Pull-down.

TRST_ICE/, TCK_ICE, TDI_ICE,
TMS_ICE

AB4, AA4, AB3, Y5

Internal Pull-down.

SCANEN, SCANMODE, IDDTN,
CLKMODE_0, CLKMODE_1,
TESTACLK, TESTCLKEN

N22, E7, Y4, AA22, AC2, AB6, D7

Internal Pull-down.

DIS_SCSI_FSN/, TESTHCLK, TN

AC4, AE2, C5

Internal Pull-up.

DIS_PCI_FSN/

A24

Internal Pull-down. Pull up
externally to enable correct
operation of the PCI FSN.

ZCR_EN/, IOPD_GNT/

N23, AC5

Internal Pull-up.

Advertising