Other features – MIDEA Dehumidifier MDP User Manual

Page 9

Advertising
background image

Page 9

Other Features

Ope

rating

In

structions

Bucket Full Light

Lights up when the bucket is ready to be
emptied.

Auto Shut Off

The dehumidifier shuts off when the bucket
is full, or when the bucket is removed or not
replaced in the proper position. When the
setting humidity is reached, the unit will be
shut off automatically. The fan motor will
continue operating.

Auto Defrost

When frost builds up on the evaporator
coils, the compressor will cycle off
and Auto Defrost function will run
automatically.

(CONTINUE) Button

Press to activate the continuous
dehumidifying operation.

(TURBO) Button

Control the Turbo speed. Press to select
either Turbo or normal fan speed. Set
the Turbo control to high for maximum
moisture removal. When room humidity
is at your preferred level, it is advised to
turn off Turbo speed.

(TIMER) Button

Starts the Timer ON and Timer OFF
function setting.

Up/Down Buttons (

/

)

• Humidity Set Control Buttons

The humidity level can be set within a
range of 35% RH (Relative Humidity)
to 85% RH (Relative Humidity) in 5%
increments.
For drier air, press the

button and

set to a lower value (%).
For damper air, press the

button and

set a higher value (%).

• TIMER Set Control Buttons

Use the

and

key buttons to set

the Timer ON or Timer OFF from 0 to
24 hours.

(POWER) Button

Press to turn the dehumidifier on and off.

LED Display

Shows the set % humidity level from 35%
to 85% or auto start/stop time (0 ~ 24)
while setting, then shows the actual (+/-
5% accuracy) room % humidity level in a
range of 30% RH (Relative Humidity) to
90% RH (Relative Humidity).

Error Codes and Protection Code:
AS

- Humidity sensor error - Unplug

the unit and plug it back in. If error
persists, contact Customer Service.

ES

- Tube Temperature sensor of the

evaporator error - Unplug the unit
and plug it back in. If error persists,
contact Customer Service.

P2

- Bucket is full or bucket is not in right

position - Empty the bucket and
replace it in the right position. (only
available for the unit with no pump
feature.)

P2

- Bucket is full - Empty the bucket.

(only available for the unit with
pump feature.)

EC

- Refrigerant leakage detection -

Display area will show EC when the
unit detects refrigerant leakage. If
error persists, contact Customer
Service.

E3

- Unit malfunction - Unplug the unit

and plug it back in. If error persists,
contact Customer Service.

Eb

- Bucket is removed or not in right

position - Replace the bucket in the
right position. (only available for the
unit with pump feature.)