Clearances optional floor stand installation – Empire Comfort Systems BF-30-2 User Manual

Page 8

Advertising
background image

Page 8

16943-5-0806

SRS-18* and SRS-30 Floor Stand Installation

1. Align clearance holes on floor stand with screw holes on

bottom of heater, as shown in Figure 5.

2. Attach floor stand to heater with (4) screws provided with

floor stand.

3. Connect the gas line.

* SRS-18 floor stand can not be used in a bedroom

installation.

BF-10 must be wall mounted in a bedroom installation.
Installation on Rugs and Tile

If this appliance is installed directly on carpeting, tile or other

combustible material, other than wood flooring, the appliance shall

be installed on a metal or wood panel extending the full width and

depth of the appliance.
Attention: Optional SRS-18 and SRS-30 Floor Stand meets

requirement.
The base referred to in this section does not mean the fire-proof

base as used on wood stoves. The protection is for rugs that are

extremely thick and light colored tile.

Figure 5

BF-30

Figure 4

BF-10 and BF-20

Figure 3

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.

Do not install in alcove or closet.

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

BF-10/BF-20

BF-30

Left side

5" (127mm)

8" (203mm)

Right side

5" (127mm)

8" (203mm)

Rear wall

0" (0mm)

0" (0mm)

Ceiling

36" (914mm)

36" (914mm)

Minimum vertical clearance from a projections above

the appliance (shelves, window sills, etc.)

36" (914mm)

36" (914mm)

Floor (top surface of carpeting, tile, etc.)

2" (51mm)

2" (51mm)

CLEARANCES

OPTIONAL FLOOR STAND INSTALLATION

Advertising
This manual is related to the following products: