Wall mount installation – Empire Comfort Systems BF-30-2 User Manual

Page 9

Advertising
background image

16943-5-0806

Page 9

On Sheet Rock Wall

1. After locating mounting holes, drill (4) 5/16" (8mm) diameter

holes into the wall.

2. Insert (4) plastic expansion anchors provided into the

holes.

3. Tighten (4) #10 x 1" (25mm) screws provided into the plastic

expansion anchors. Do not completely tighten screwheads

to the plastic expansion anchors, leave a 1/8" (3mm) gap

between screwheads and plastic expansion anchors.

4. Mount heater onto the (4) screwheads and complete tightening

the screwheads to the plastic expansion anchors.

Attention! Use the following steps to properly align the upper

louver and the reflector with the heat shield.

a. When replacing upper louver, be sure the bottom lip of

upper louver goes behind the heat shield.

b. When replacing reflector, be sure the top lip of reflector

goes in front of the heat shield.

5. Connect the gas line.

Figure 8

OUTLINE OF
OUTER CASING

MOUNTING HOLE LOCATIONS

VIEWED FROM FRONT OF HEATER

FLOOR

2” (51mm) MIN.

2 1/32” (52mm)

4 1/32”
(102mm) MIN.

18 7/8”

(479mm)

1 3/32”

(28mm)

24 1/8” (613mm)

20 1/8” (511mm)

2”

(51mm)

2”

(51mm)

22”

(559mm)

BF-30

Figure 7

BF-10 and BF-20

Figure 6

Refer to Figures 6 and 7 for measurements in order to locate (4) mounting holes on wall. Figures 6 and 7 are the front views of the

heater.

1. Remove lower louver from casing assembly (2 screws).

2. Remove reflector from casing assembly (2 screws).

3. Remove upper louver from casing assembly (2 screws).
On Solid Wall

1. After locating mounting holes, attach (4) #10 x 1" (25mm) screws provided into the wall. Do not completely tighten screwheads

to the wall, leave a 1/8" (3mm) gap between screwheads and wall.

2. Mount heater onto the (4) screwheads and complete tightening screwheads into the wall.

Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield.

a. When replacing upper louver, be sure the bottom lip of upper louver goes behind the heat shield.

b. When replacing reflector, be sure the top lip of reflector goes in front of the heat shield.

3. Connect the gas line.

18” (457mm)

14” (356mm)

2”

(51mm)

2”

(51mm)

1 3/32”

(28mm)

18 7/8”

(479mm)

OUTLINE OF
OUTER CASING

4 1/32”
(102mm) MIN.

2 1/32” (52mm)

MOUNTING HOLE LOCATIONS

VIEWED FROM FRONT OF HEATER

FLOOR

2” (51mm) MIN.

22”

(559mm)

WALL MOUNT INSTALLATION

Advertising
This manual is related to the following products: