Everpure MRS Reverse Osmosis System MRS-100CC User Manual

Page 2

Advertising
background image

Inlet

(without optional Pre-filter)

Pre-filter

(optional)

Outlet

MRS

Processor

6TO-BW

Carbon

Cartridge

MR-

RO Cartridge

7CC-BW

Cartridge

(optional)

Storage

Tank

(not shown,

not

included)

RO Reject

(1/4" John

Guest) route

to drain

figure 1. Back view of Prefilter bracket.

Wing

bracket

Prefilter bolts

figure 2. MRS Assembly.

2

Inlet

(with Pre-filter)

noteS:

Please read this manual prior to installing and operating the

system.

Incoming water supplies that do not meet these requirements

may need additional pre-treatment prior to the system. System

performance may be affected if requirements are not met,

including system output production and cartridge change-out

frequency.

If the supply pressure exceeds 80 PSI, install a pressure reducing

valve. Adjust the pressure reducing valve to the required

operating pressure, not to exceed 80 PSI.

Consult with your local building inspector for approval and

required permits to install this system. Additional equipment, such

as back-flow prevention devices, seismic restraint equipment, air

gaps, etc., may be required. Completed installation must meet all

local and national codes.

Do not connect the MRS system after any water filtration system,

unless specifically provided for use with the MRS.

unPackIng and InSPectIon

The MRS includes all the necessary fittings for installation. Lengths

of 1/4” tubing have been provided for connecting to the wastewater/

drain connection. Supply lines and distribution piping/tubing are not

included.
The MRS system is packaged as a complete unit in two cartons. At a

minimum, you should have the following:

carton 1

Plate mounted processor assembly (Including the following)

1.

pump

A.

cartridge heads

B.

transformer

C.

carton 2

TO cartridge

1.

RO cartridge

2.

Calcium carbonate (CC) cartridge (optional)

3.
Inspect the cartons for damage. Report any damage to freight

carrier immediately. Carefully unpack each item. Save the packaging

material temporarily, as it may be used to protect painted surfaces

during assembly.

SySteM aSSeMbly

The MRS is configured as a two piece unit; with the processor

mounted on a vertical surface and the storage tank located nearby.
Locate the system in an area that is convenient to the inlet water

supply and drain facilities, with access for routing the product water

tubing/piping to the equipment. Install in a dry location, away from

all forms of corrosive and/or flammable materials. Consider ease of

access for servicing when selecting a location.

Processor assembly Mounting

If the optional Pre-filter has been supplied, go to step to 2. If not

1.

supplied, go to step 5.
Position the MRS processor assembly so the rear of the

2.

mounting plate is accessible. Secure the wing bracket to the rear

of the mounting plate as shown Figure 1. Use the 5/16” hex bolts

and washers provided. Align the wing bracket so it is inward

and upward as far as possible – use a combination square to

maintain alignment. Tighten both bolts securely.
Attach Pre-filter head to Pre-filter bracket with 5/16” hex bolts,

3.

nuts and washers provided.
Insert elbow fitting into solenoid valve inlet. Connect 1/4” OD

4.

tubing between pre-filter outlet and elbow fitting on solenoid

valve.

5. The processor framework has 6 mounting holes (3 keyhole

slots, 3 standard) on 4.5” centers for securing to a stationary

vertical surface. Evaluate the mounting surface for its ability

to properly support the weight of the processor when in

operation (Approximately 40 pounds).

continued on the next page . . .

by-pass Plug

(Keep inserted if optional

7CC-BW cartridge is not used)