Everpure MRS Reverse Osmosis System MRS-100CC User Manual

Page 7

Advertising
background image

troubleShootIng guIde

Problem

Possible cause

remedy

Insufficient product water

1.

during normal operating

periods.

a. Pre-filter cartridge plugged.

Replace pre-filter cartridge.

a.

TO cartridge plugged.

b.

Replace TO cartridge.

b.

RO cartridge plugged.

c.

Replace RO cartridge.

c.

Insufficient system inlet pressure.

d.

Check/repair booster pump and inlet line.

d.

e. Incorrect storage tank pre-charge.

e. Empty water in storage tank. Check pre-charge

pressure. Adjust to 5-10 psi (typical). Presence

of water at Schrader valve indicates failed

bladder - Replace bladder or tank.

Insufficient product water

2.

volume during peak periods.

Refer to problem 1.

a.

Refer to problem 1.

a.

System rated output low for application.

b.

Verify system output. If output is within

b.

specification, increase output if applicable.

System storage capacity low.

c.

Increase storage capacity if applicable.

c.

Low quality RO water.

3.

Refer to problem 1.

a.

Refer to problem 1.

a.

RO cartridge failure.

b.

Replace RO cartridge.

b.

Low water pressure at water

4.

using equipment.

Tubing/piping run to equipment restrictive.

a.

Increase tubing/piping diameter. Refer

a.

to "System Installation" section for

recommendations.

Incorrect storage tank pre-charge.

b.

Empty water in storage tank. Check pre-charge

b.

pressure. Adjust to 5-10 psi (typical). Presence

of water at Schrader valve indicates failed

bladder - Replace bladder or tank.

Objectionable product water

5.

odor.

TO cartridge exhausted.

a.

Replace TO cartridge.

a.

Storage Tank requires disinfection.

b.

Disinfect storage tank.

b.

Wastewater flow too low or

6.

decreases over time.

Drain line restricted.

a.

Check/correct any restrictions in drain line

a.

tubing. Make sure to allow an air gap at the

drain. Disconnect reject line at quick connect

fitting and inspect for obstruction or damage.

Remove obstruction. Replace if required.

Insufficient system inlet pressure.

b.

Check/repair booster pump and inlet line.

b.

7

Advertising