• With the exhaust blower removed, use a utility vacuum to remove any ash

accumulation in the exhaust blower tube.

• Use a soft paint brush and carefully remove any ash accumulation from the

inside of the exhaust blower and from the exhaust blower fan blade.

• Inspect the exhaust blower motor for dust accumulation and carefully

remove it, ensuring that all air cooling holes into the motor are open and free
of dust deposits.

• Install the blower and side panel in the reverse order as described above.

Remember to check the condition of the exhaust blower gasket AND
remember to reconnect the thermal sensor to the top of the exhaust blower
outlet before reinstalling the side panel.