Replacing components – England's Stove Works 25-EPI User Manual

Page 38

Advertising
background image

Page | 38

REPLACING COMPONENTS

Convection Blower

1. Before beginning any component

replacement, be certain the unit is
unplugged and thoroughly cooled
down.

2. In order to access the combustion

blower, the unit will have to be at
least partially removed from the
fireplace opening (or alternatively,
the surround kit and side panels can
be removed to access the blower).

3. Detach the convection blower from

the wiring harness before loosening
the four screws which secure it to the
convection shroud of the stove.

4. After loosening and remove the four

screws which hold the blower to
stove, remove the blower from the
stove.

5. Installation of the new blower is

performed exhaust in reverse of
removal; remember to reconnect the
new blower to the wiring harness. .

Combustion Blower

1. Before beginning any component

replacement, be certain the unit is
unplugged and thoroughly cooled
down.

2. Remove the unit from the fireplace.

3. Disconnect the venting system from

the exhaust blower, and disconnect
the exhaust blower from the stove
wiring harness. Loosen and remove
the thermal sensor screw on the top
of the exhaust blower outlet using a
5/16” wrench.

4. Loosen and remove all five screws

which hold the exhaust blower to the
exhaust blower tube. Once the
screws have been removed the
blower can be lifted up and out of the
stove.

5. Reinstallation is the exact opposite

of the steps above; however be
certain to check the condition of the
exhaust blower gasket and replace if
necessary.

Advertising
This manual is related to the following products: