Command/response table for sis commands, Command/response table for sis commands, Preliminar y – Extron electronic VLM 2000 User Manual

Page 36: Configuration and control, cont’d

Advertising
background image

SIS

Configuration and Control, cont’d

VoiceLift

Microphone • SIS Configuration and Control

3-4

PRELIMINAR

Y

Command/response Table for SIS Commands

Command

ASCII

Command

(host to

receiver)

Response

(receiver to host)

Additional description

Gain and attenuation adjustment

N

Channel A selections also apply to channel C (student microphone); channel B selections apply to channel D (student

microphone).

N

These commands are case-sensitive.

Set audio gain

X22*

*

X$

G

Chn

X22*

* Aud =

X$

]

Increase the audio level for
channel

X22*

to

X$

dB.

For

X22*

:

0 = no carrier
1 = channels A (C)
2 = channel B (D)
3 = channels A and B (C and D)

X$

= 0 to +6 dB

Example:

2*5G

Chn2*Aud=5

Set the gain (volume level) for
channel B (and D) to +5 dB.

Set audio attenuation

X22*

*

X$

g

Chn

X22*

* Aud =

X$

]

Decrease the audio level for
channel

X22*

to

X$

dB.

X$

= 0 to -6 dB

Increment audio gain

X22*

+G

Chn

X22*

* Aud =

X$

]

Increase audio volume level
(gain) for channel

X22*

in

increments of +1 dB.

Example:

3*+G

Chn3*Aud=4*

Raise the volume level for
channels A and B (and C and D)
by 1 dB (to 4 dB).

Decrement audio gain

X22*

* -G

Chn

X22*

* Aud =

X$

]

Decrease audio volume level for
channel

X22*

in steps of -1 dB.

View audio gain level

X22*

* G

Chn

X22*

* Aud =

X$

]

Status commands

View microphone status

S

Chn

X22*

]

Show current channel.

View relay state

O

Rly

X%

]

Show status of the Rly port.
For

X%

:

0 = open
1 = closed

View contact closure input state

]

Sio

X4#

]

Show status of the Ctc (contact
input) port. For

X4#

:

0 = open
1 = closed

Information requests

Request part number

N

60-938-01

]

Show part number of the
VLR 102 receiver.

Query firmware version

Q or 1Q

X1!

]

Show the VLR 102’s firmware
version (

X1!

) to two decimal

places. This query shows the
number of the currently running
version of the user-updatable
firmware.

Example:

Q

1.01

Query factory firmware version

3Q

X1!

]

Show the original firmware
version that was installed at the
factory. Factory firmware is not
user-replaceable.

Advertising