Feeding current

Iac = x.xA

Feeding current amount in xx.x A

PV array voltage

Vdc = xxx.x V

Input voltage from PV array, xxx.x VDC

Daily Energy

Etoday=xxx.xxKW

h

The accumulated kWh of that day

System Fault

Isolation failure

Isolation fault

Earth fault of the PV-panels or failure of

surge voltage protection

GFCI active

Ground I fault

Leakage current detected from ground

conductor is too high

Grid failure

Grid fault

Grid measured data is beyond the

specification (voltage & frequency)

No utility

No Utility

Utility is not available

Input voltage too high

PV over voltage

Input voltage is higher than the maximum

input voltage

Inverter Fault

Consistent failure

Consistent Fault

The readings of 2 microprocessors are not

consistent. It could be caused by CPU

and/or other circuit do not function well.

Temperature too high

Over temperature

The internal temperature of inverter is

higher than normal value

Output relay failure

Relay Failure

The relay between inverter and grid is not

functional

Output DC injection too high

DC INJ High

Output DC injection is higher than

expected

EEPROM problem

EEPROM Failure EEPROM inside has data access problem

Communication failure
between microprocessors

SCI Failure

The communication between MCU inside

is abnormal