Eaton Electrical ETN2000 User Manual

Page 31

Advertising
background image

Over

Temperature

1.

The internal temperature is higher

than

specified normal value

2. Find a way to reduce the ambient temperature.
3. Or move the inverter to a cooler environment
4. If it is not effective, please contact Eaton.

Relay Failure

DC INJ High

EEPROM

Failure

SCI Failure

High DC Bus

Low DC Bus

Ref 2.5V Fault

DC Sensor

Fault

GFCI Failure

1. Disconnect

ALL PV (+) or PV (-)

2. Wait for few seconds
3. After the LCD switches off, reconnect and

check again

4. If the message reappears, please contact

Eaton.

z If there is no display on the panel, please check PV-input connections.

If the voltage is higher than 150V, call your local service.

z During periods of little or no sunlight, the PV-Inverter may continuously

start up and shut down. This is due to insufficient power generated to

operate the control circuits.