6. Inverter Status

Inverter is designed to be user-friendly. Therefore, the status of the Inverter

can be easily understood by reading the information that shown on the front

panel display. All possible messages are shown in the following table.

Display information

Operating conditions

In English

Description

Normal Working Status

Power off

No display

PV inverter is totally shutdown, V

PV

<70V

Standby

Standby

70V≦ Input voltage <100V

Initialization & waiting

Waiting

Input voltage range 100~150V during

start-up. After PV voltage is higher than

100V, inverter is waiting for feeding to grid

Check grid

Checking xxxS

When PV voltage> 150V, inverter is

checking feeding conditions

Feeding grid, MPPT

Normal

Inverter is feeding power. After 10 seconds

of this display, LCD will show wattage.

FLASH

FLASH

FLASH firmware

Monitoring Parameters

Instantaneous Output power

Pac =xxxx.xW

The real time output power in xxxx W

Accumulated energy
information

Eac=xxxxxxkWh

Total energy that has been fed to grid since

inverter was installed

Grid voltage

Vac = xxx.xV

Grid voltage in xxx.x VAC

Grid frequency

Frequency=xx.xHz

Grid frequency in xx.x Hz