Cable connection to lc fiber-optic connectors -13, Figure 4‐11 – Enterasys Networks 7S4280-19-SYS User Manual

Page 53

Advertising
background image

Connecting to the Network

Enterasys NAC Controller Hardware Installation Guide 4-13

Figure 4-11 Cable Connection to LC Fiber-Optic Connectors

3.

Verify that a link exists by checking that the port RX LED is on (flashing amber, blinking 
green, or solid green). If the RX LED is off, perform the following steps until it is on:

a.

Verify that the device at the other end of the segment is ON and connected to the segment.

b. If there are separate fiber‐optic connections on the other device, check the crossover of the 

cables. Swap the cable connections if necessary.

c.

Check that the fiber‐optic connection meets the dB loss and cable specifications outlined 
in the Cabling Guide for multimode fiber‐optic cabling. To obtain this document, refer to 

Related Documents”  on page xvi

If a link has not been established, refer to 

Chapter 5

 for LED troubleshooting details. If a 

problem persists, refer to 

Getting Help”  on page xviii

 for details on contacting 

Enterasys Networks for support.

4.

Repeat steps 1 through 3, above, until all connections have been made.

1 Installed Mini-GBIC LC connector

4 Receive LED (RX)

2 LC cable connector

5 Transmit LED (TX)

3 Release tab