Recommended shutdown procedure, Last resort shutdown procedure – Enterasys Networks 7S4280-19-SYS User Manual

Page 67

Advertising
background image

Overview of the NAC Controller PEP Shutdown Procedure

Enterasys NAC Controller Hardware Installation Guide 5-7

Recommended Shutdown Procedure

Before pulling a NAC Controller PEP out of a chassis, 

press or tap on its 

OFFLINE/RESET

 switch for less than 1 second. 

Its CPU LED changes from solid green to blinking between green and amber, indicating that the 
module is shutting down. At the end of the shutdown routine, the CPU LED changes to a 
67%/33% sequence of amber/off, respectively, indicating the module is in a halt state. In this time it 
is safe to restart or remove the module from the chassis.

When a controlled shutdown is initiated from the 

OFFLINE/RESET switch

, you have 60 seconds 

from the time the CPU starts alternately flashing amber/off until the device automatically restarts.

Last Resort Shutdown Procedure

To reset a NAC Controller PEP without it performing an orderly shutdown routine, 

press and hold the

OFFLINE/RESET

 switch for approximately 6 seconds. 

Pulling any NAC Controller PEP out of the chassis before it has been shut down is not 
recommended. The only safe time to pull a module out of the chassis is after the completion of a 
shutdown and the management LED is alternately flashing amber/off.

Caution: Do not remove a NAC Controller PEP from an operating chassis system before reading
the following information and instructions.

Precaución: Antes de retirar los módulos DFE del chasis en funcionamiento, lea las siguientes
instrucciones y la información suministrada.

Note: The only safe time to pull a chassis out of the chassis is when the CPU LED is alternately
flashing amber/off. Otherwise, system operation will be interrupted.

Caution: This method of shutting down a NAC Controller PEP is not recommended except as a last
resort, because all processes currently running on the module will be interrupted resulting in loss of
frames.
Precaución: No se recomienda utilizar este método para apagar los módulos DFE. Recurra a él
sólo como último recurso, puesto que interrumpe todos los procesos del módulo en
funcionamiento, lo que podría resultar pérdidas de frames.