2.

If the picture appears and is stable, but it has ghosting or

blooming, verify the video input is properly terminated. If

the problem is not resolved by changing the termination,

try using a different input cable. Poor quality or damaged

cable can cause ghosting or blooming.

3.

If the picture still is not displayed correctly, call the Extron

S

3

Sales and Technical Support Hotline.

If the interface does not respond to horizontal shifting

If the picture does not move on screen when the horizontal

shift control knob is rotated, DDSP is in use. Set the DDSP DIP

switch to Off.