Connecting to Console Port for Local Management

3-18 Hardware Installation

Connecting to Console Port for Local Management

This section describes how to install an RS232 DTE interface cable to a PC, a VT series 
terminal, or a modem to a SecureStack B2G124‐24, B2G124‐48, or B2H124‐48 for out‐of‐
band sessions using CLI commands. 

What Is Needed

The following is a list of user‐supplied DTE interface cables that may be needed to connect 
the DB9 male Console port connector on the switch. The cables are terminated by a DB9 
female connector at one end, and by one of three type connectors at the other end, 
depending on the type connection needed for the remote device. The cables that may be 
needed are as follows:

DB9 female‐to‐DB9 female

DB9 female‐to‐DB25 female 

DB9 female‐to‐DB25 male

Using a DTE modem DB9 female‐to‐DB9 female cable, you can connect products 
equipped with a DB9 DTE male console port to an IBM or compatible PC running a VT 
series emulation software package.

Using a DTE modem DB9 female‐to‐DB25 female cable, you can connect products 
equipped with a DB9 DTE male console port to a VT series terminal or VT type terminals 
running emulation programs for the VT series.

Using a DTE modem DB9 female‐to‐DB25 male cable, you can connect products equipped 
with a DB9 DTE male console port to a Hayes compatible modem that supports 
9600 baud.

The cable used must connect the Console port Received Data, Pin 2 to the Transmitted 
Data pin at the other end of the cable. The connection from the Console port Transmitted 
Data, Pin 3 (must be connected) to the Received Data pin cable connection at the other end 
of the cable. The DB9 Console port pin assignments are shown in 

Figure 3‐9

.

Note: When switches are connected in a stack configuration and all high-speed stacking
cables are connected before powering up the switches, one switch in the stack will be
automatically designated as the Manager of the stack and its Console port will remain
active. All other switches will become Member switches and their Console ports will be
deactivated.