English troubleshooting guide, Troubleshooting codes – Epson D55168 User Manual

Page 17

Advertising
background image

17

English

Troubleshooting Guide

This section provides a list of the more frequently encountered malfunctions, their causes and corrective actions. The operator or maintenance
personnel can perform some corrective actions, and others may require the assistance of a qualified D

E

WALT technician or your dealer.

Problem

Code

Excessive air tank pressure-safety valve pops off ......................................................................1, 2
Air leaks .................................................................................................................................... 3
Air leaks in air tank or at air tank welds .................................................................................... 4
Air leaks between head and valve plate .................................................................................... 5
Air leaks from safety valve ......................................................................................................... 6
Knocking Noise .......................................................................................................................... 6
Pressure reading on the regulated pressure gauge drops when an accessory is used ........... 7
Compressor is not supplying enough air to operate accessories.............................................. 8, 9, 10, 11, 12, 22
Regulator knob has continuous air leak .................................................................................... 13
Regulator will not shut off air outlet ........................................................................................... 13
Motor will not run ....................................................................................................................... 6, 14, 15, 16, 17, 18, 19, 20
Squealing Sound ....................................................................................................................... 21

Troubleshooting Codes

CODE

POSSIBLE CAUSE

POSSIBLE SOLUTION

1

Pressure switch does not shut off motor when
compressor reaches cut-out pressure

Set the On/Off switch to OFF, if the unit does not shut off contact
a D

E

WALT factory service center or a D

E

WALT authorized service

center.

2

Pressure switch cut-out too high

Contact a D

E

WALT factory service center or a D

E

WALT authorized

service center.

3

Tube fittings are not tight enough

Tighten fittings where air can be heard escaping. Check fittings
with soapy water solution. Do Not Overtighten.

Advertising