CODE

POSSIBLE CAUSE

POSSIBLE SOLUTION

15

Tank pressure exceeds pressure switch cut-in
pressure

Motor will start automatically when tank pressure drops below cut-
in pressure of pressure switch.

16

Extension cord is wrong length or gauge

Check for proper gauge wire and cord length refer to the Extension
Cords
under Installation.

17

Loose electrical connections

Check wiring connection inside pressure switch and terminal box
area.

18

Possible defective motor

Contact a D

E

WALT factory service center or a D

E

WALT authorized

service center.

19

Paint spray on internal motor parts

Contact a D

E

WALT factory service center or a D

E

WALT authorized

service center. Do not operate the compressor in the paint spray
area. See flammable vapor warning.

20

Fuse blown, circuit breaker tripped

1. Check fuse box for blown fuse and replace as necessary. Reset

circuit breaker. Do not use a fuse or circuit breaker with higher
rating than that specified for our particular branch circuit.

2. Check for proper fuse. You should use a time delay fuse.
3. Check for low voltage conditions and/or proper extension cord.
4. Disconnect the other electrical appliances from circuit or operate

the compressor on its own branch circuit.

21

Worn Belt

Contact a D

E

WALT factory service center or a D

E

WALT authorized

service center.

22

Restricted air intake filter

Clean or replace air intake filter. Do not operate the air compressor
with the filter removed. Refer to the Air Filter paragraph in the
Maintenance section.