English – Epson D55168 User Manual

Page 18

Advertising
background image

18

English

CODE

POSSIBLE CAUSE

POSSIBLE SOLUTION

4

Defective air tank

Air tank must be replaced. Do not repair the leak.

WARNING: Risk of bursting. Do not drill into, weld or other-

wise modify air tank or it will weaken. The air tank can rupture or
explode.

5

Leaking seals

Contact a D

E

WALT factory service center or a D

E

WALT authorized

service center.

6

Defective safety valve

Operate safety valve manually by pulling on ring. If valve still leaks,
it must be replaced.

7

Regulator is not adjusted correctly for accessory
being used

It is normal for some pressure drop to occur when an accessory
is used, adjust the regulator as instructed in Regulator under
Features
if pressure drop is excessive.
NOTE: Adjust the regulated pressure under flow conditions while
accessory is being used.

8

Prolonged excessive use of air

Decrease amount of air usage.

9

Compressor is not large enough for accessory

Check the accessory air requirement. If it is higher than the CFM
or pressure supplied by your air compressor, a larger compressor
is needed to operate accessory.

10

Hole in air hose

Replace air hose.

11

Check valve restricted

Remove, clean or replace.

12

Air leaks

Tighten fittings.

13

Regulator is damaged

Replace.

14

Motor overload protection switch has tripped

Refer to Motor Overload Protection under Features. If motor over-
load protection trips frequently, contact a D

E

WALT factory service

center or a D

E

WALT authorized service center.

Advertising