For rack mount model – EMC 4K VA 20K VA UPS User Manual

Page 18

Advertising
background image

30

Net Weight kg (lb)

W/O ISOTR

50 (110)

86.0 (189.2)

80(176)

Shipping Weight kg

(lb) W/O ISOTR

53 (116.7)

106.0 (233.2)

101.5(223.3)

Dimensions W x D

x H mm (inch) W/

ISOTR

257 x 590 x 700

(10.1"x23.2"x27.6")

342 x 690 x 715

(13.4" x 27.2" x

28.1")

Net Weight kg (lb)

W/ ISOTR

123.0 (270.6)

130 (286.0)

Shipping Weight kg

(lb) W/ ISOTR

145.0 (319.0)

151.5 (333.3)

Operating

Temperature

0~40°C / 32~104°F

Storage

Temperature

-20~50°C / -4~122°F

Altitude

3,500 meters max

Audible Noise (1

meter from surface)

50 dBA

< 55 dBA

Environment

Relative Humidity

0 ~ 95% humidity, non-condensing

Safety

UL 1778, CE

EMC (EMS / EMI)

IEC 61000-4, FCC Part 15, CISPR 22

Conformance

Equipment

Protection Policy

Warranty policy may vary depends on region


Tower model (with LCD display)

VGD-10000

VGD-12000

VGD-15000

VGD-20000

Capacity (VA)

10000VA

12000VA

15000VA

20000VA

Capacity

Capacity (W)

7000W

8400W

10500W

14000W

Voltage (on battery)

100V, 110V, 115V, 120V / 208V, 220V, 230V, 240V +/-2% (Selectable Output Voltage)

Frequency (on

battery)

50 / 60 Hz +/-0.5%

Transfer Time

0 ms

Overload Recovery

Auto transfer to UPS

High Efficiency

mode (AC to AC)

> 97 %

UPS Design

Technology

On-Line / Fully digitized microprocessor controlled

Output Wave Form

Sine wave

Harmonic distortion

< 3% of T.H.D. at linear load

Output

Crest Factor

3 : 1

Surge Protection

IEC61000-4-5 level 3

Overload Protection

125% for 1 minutes and 150% for 10 seconds (On-line) 130% for 10 seconds and 150%

for 1.5 seconds (On-battery)

Protection and

Filtering

Short Circuit

Protection

UPS output cut off immediately or input fuse / circuit breaker protection

Visual Display (LED

model)

UPS on(green), line-mode(green), battery mode(yellow), bypass(yellow), fault(red)

Visual Display

(LCD model)

Input / output voltage, input / output frequency, on-line mode, back up mode, battery

capacity, load level

Audible Alarm

(Battery back-up)

Beep every 5 sec

UPS Fault

Continuous beeping sound and LCD display

System/Display

/Warning

Communication

RS-232 Serial Port and USB

Type

Sealed, maintenance-free lead acid batteries

DC Voltage (V)

Battery (Tower )

240V / 12V9AH

x 20

240V / 12V7.2AH

x 20 x 2SET

240V / 12V7.2AH

x 20 x 2SET

240V / 12V9AH

x 20 x 2SET

Typical Recharge

Time to 90% Full

4 hours

Management

Self-test, adjustable battery transfer points and alarm settings

Battery

Battery Protection

Cut off without draining any current when battery is low

31

Cold Start (DC

start)

YES

Back Up Time

(Tower model)

About 4~6 min Full load / 10~15min Half load

Input Inlet

Hardwire

Receptacles

Hardwire

Dimensions W x D

x H mm (inch) W/O

ISOTR

257 x 690 x 715

(10.1" x 27.2" x

28.1")

342 x 690 x 905

(13.5"x27.2"x35.6")

342 x 760 x 905 (13.5" x 29.9" x 35.6")

Net Weight kg (lb)

W/O ISOTR

80 (176)

130 (286)

207 (455.4)

Shipping Weight kg

(lb) W/O ISOTR

101.5 (223.3)

151.5 (333.3)

225 (495.0)

Dimensions W x D

x H mm (inch) W/

ISOTR

342 x 690 x 715

(13.4" x 27.2" x

28.1")

342 x 690 x 905

(13.5"x27.2"x35.6")

342 x 760 x 905 (13.5" x 29.9" x 35.6")

Net Weight kg (lb)

W/ ISOTR

130 (286)

180 (396)

274 (602.8)

Physical

Shipping Weight kg

(lb) W/ ISOTR

151.5 (333.3)

201.5 (443.3)

292 (642.4)

Operating

Temperature

0~40°C / 32~104°F

Storage

Temperature

-20~50°C / -4~122°F

Altitude

3,500 meters max

Audible Noise (1

meter from surface)

< 55 dB

Environment

Relative Humidity

0 ~ 95% humidity, non-condensing

Safety

UL 1778, CE

EMC (EMS / EMI)

IEC 61000-4, FCC Part 15, CISPR 22

Conformance

Equipment

Protection Policy

Warranty policy may vary depends on region

For Rack mount model

RM model (with LCD display)

VGD-4000

VGD5000

VGD-6000

VGD-10000

Capacity (VA)

4000VA

5000VA

6000VA

10000VA

Capacity

Capacity (W)

2800W

3500W

4200W

7000W

Voltage (on battery)

208V, 220V, 230V, 240V +/-2% (Selectable Output Voltage)

Frequency (on

battery)

50 / 60 Hz +/-0.5%

Transfer Time

0 ms

Overload Recovery

Auto transfer to UPS

High Efficiency

mode (AC to AC)

> 95 %

> 97 %

UPS Design

Technology

On-Line / Fully digitized microprocessor controlled

Output Wave Form

Sine wave

Harmonic distortion

< 3% of T.H.D. at linear load

Output

Crest Factor

3 : 1

Surge Protection

IEC61000-4-5 level 3

Overload

Protection

125% for 1 minutes and 150% for 10 seconds (On-line) 130% for 10 seconds and 150%

for 1.5 seconds (On-battery)

Protection and

Filtering

Short Circuit

Protection

UPS output cut off immediately or input fuse / circuit breaker protection

Visual Display

(LED model)

UPS on(green), line-mode(green), battery mode(yellow), bypass(yellow), fault(red)

Visual Display

(LCD model)

Input / output voltage, input / output frequency, on-line mode, back up mode, battery

capacity, load level

Audible Alarm

(Battery back-up)

Beep every 5 sec

System/Display

/Warning

UPS Fault

Continuous beeping sound and LCD display

Advertising