TROUBLESHOOTING

NOTE: All troubleshooting items are listed in order of operation and likely occurrence.

WARNING: Only a qualified service person should service and repair heater.

CAUTION: Never use a wire needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

Make sure grille guard is in place before running heater. If screen or grille guard is removed for servicing it must be

replaced prior to operating the heater.

WARNING: If you smell gas:

Shut off gas supply

Do not try to light any appliance

Do not touch any electrical switch; do not use any phone in your building

Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remov-

er, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with com-

bustion air and create odors and possible discoloration of walls and ceilings.

OBSERVED SYMPTOM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed in, there is a

spark at the ODS/pilot but no ignition

1. Control knob not fully pressed in.

2. Control knob not pressed in long enough

3. Equipment shutoff valve not fully open

4. Thermocouple connection loose at control valve

5. Pilot flame not touching thermocouple, which allows

thermocouple to cool, causing pilot flame to go out.

This problem could be caused by one or both of the

following:

a. Low gas pressure

b. Dirty or partially clogged ODS/pilot

6. Thermocouple damaged

7. Control valve damaged

1. Press in control knob fully

2. After ODS/pilot lights, keep control knob pressed in

for 30 seconds

3. Fully open equipment shutoff valve

4. Hand tighten thermocouple nut until snug, and then

tighten 1/4 turn more.

5. -

a. Contact local gas company

b. Clean ODS/pilot (see Cleaning and Maintenance,

page 11).

6. Replace thermocouple

7. Replace Control valve.

Burner does not light after ODS/pilot is lit

1. Burner orifice is clogged

2. Burner orifice diameter to small

3. Inlet gas pressure is too low

1. Clean burner orifice (see Cleaning and Maintenance

on page 11), or replace burner orifice

2. Replace burner orifice

3. Contact local gas company

Delayed ignition of burner

1. Manifold pressure is too low

2. Burner orifice is clogged

1. Clean burner orifice (see Cleaning and Maintenance

on page 11), or replace burner orifice

Burner backfiring during operation

1. Burner orifice is clogged or damaged

2. Burner damaged

3. Gas regulator defective

1. Clean burner orifice (see Cleaning and Maintenance

on page 11), or replace burner orifice

2. Replace burner

3. Replace gas regulator

Burner plaque(s) does not glow [Infrared

Only]

1. Plaque damaged

2. Control knob set between locked positions.

3. Inlet gas pressure is too low

1. Replace burner

2. Turn control knob until it locks at desired setting.

3. Replace gas regulator

Slight smoke or odor during initial operation

1. Residues from manufacturing process

1. Problem will stop after a few hours of operation

Heater produces a whistling noise when

burner is lit

1. Turning control knob to HI position when burner is cold

2. Air in gas line

3. Air passageways on heater blocked

4. Dirty or partially clogged burner orifice.

1. Turn control knob to LO position and let warm up for

a minute.

2. Operate burner until air is removed from line have

gas line checked by local gas company.

3. Observe minimum installation clearances (see Figure

4 page 6)

4. Clean burner orifice (see Cleaning and Maintenance

on page 11), or replace burner orifice.

White powder residue forming within burner

box or on adjacent walls or furniture

1. When heated, vapors from furniture polish, wax, carpet

cleaners, etc., turn into white powder residue

1. Turn heater off when using furniture polish, wax,

carpet cleaner or similar products.

Heater produces unwanted odors.

1. Heater burning vapors from paint, hair spray, glues, etc.

See IMPORTANT statement above

2. Gas leak. See WARNING statement at top of page.

1. Ventilate room. Stop using odor-causing products

while heater is running.

2. Locate and correct all leaks (see Checking Gas Con-

nections, page 9)