Precautions – Enerco HSVFR10LPT User Manual

Page 3

Advertising
background image

3

Installation Instructions and Owner’s Manual

Unvented Liquid Propane Fired Room Heater

DANGER: Carbon monoxide poisoning may lead to

death.

Carbon Monoxide Poisoning:

Early signs of carbon monoxide poisoning resemble the

flu, with headaches, dizziness, or nausea. If you have

these signs, the heater may not be working properly.

Get fresh air at once! Have heater serviced. Some

people are more affected by carbon monoxide than oth-

ers. These include pregnant women, persons with heart

or lung disease or anemia, those under the influence of

alcohol, and those at high altitudes.

Propane/LP Gas:

Propoane/LP gas is odorless. An odor making agent is

added to propane/LP gas. The odor helps you detect

a Propane/LP gas leak. However the odor added to

propane/LP gas may be present even though no odor

exists. Make certain you read and understand all warn-

ings. Keep this manual for reference. It is your guide to

safe and proper operation of this heater.

Product Features

Figure 1

PRECAUTIONS:

1. BF-10 LP and IR-10LP may be installed in a bed-

room, but not a bathroom, or any place where a

strong wind would shut down the appliance.

2. This heater needs outside ventilation air to run

properly. The Oxygen Depletion Sensor (ODS) safety

shutoff system shuts down the heater if not enough

fresh air is available. See Fresh Air for Combustion

and Ventilation, page 3.

3. Keep all air openings in heater clear, free of debris

or any blockage. This will insure that enough air for

proper combustion enters the heater.

4. If heater shuts off, do not relight until you provide

fresh, outside air. If heater keeps shutting off, it re-

quires servicing.

5. Turn off and let cool before servicing. Only a quali-

fied service person should service and repair heater.

6. Do not run heater:

• Where flammable liquids or vapors are used or stored
• During dusty conditions.

7. Before using furniture polish, wax, carpet cleaner or

similar products, turn heater off. If heated the vapors

from these products may create a white powder

residue within burner box or on adjacent walls or

furniture.

8. Do not use heater if any part has been underwater.

Immediately call a qualified service technician to in-

spect the room heater and to replace any part of the

control system and any gas control which has been

underwater.

9. Operating heater above elevations of 4,500 feet

could cause pilot/ODS to shutdown heater.

10.Always run heater with control knob in a locked posi-

tion. Never set control knob between locked posi-

tions. Poor combustion and higher levels of carbon

monoxide may result if control knob is left between

locked positions.

Control Knob

Grill

Front Panel

Burners

Heater

Cabinet

SPECIFICATIONS

IR10 LP

BF10LP

BTU (Available)

10,000

10,000

Type of Gas

LP-Gas Only

LP-Gas Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

10 Inches of Water

10 Inches of Water

Inlet Gas Pressure (Maximum)

14 Inches of Water

14 Inches of Water

Inlet Gas Pressure (Minimum)

11 Inches of Water

11 Inches of Water

Burners / Orifice nozzles

2

1

Thermostatic Control

No

No

Clearances: inches (mm)

Top

36” (915cm)

36” (915cm)

Sides

6” (152cm)

6” (152cm)

Floor (min. to top of carpet)

2” (51cm)

2” (51cm)

Fabric / flammable objects

36” (915cm)

36” (915cm) 36” (915cm)

Advertising
This manual is related to the following products: