Empire Comfort Systems SR-10T-3 User Manual

Page 22

Advertising
background image

16941-5-0907

Page 22

Wiring

The appliance, when installed, must be electrically grounded in accordance

with local codes or, in the absence of local codes, with the National Electri

-

cal Code, ANSI/NFPA 70, if an external electrical source is utilized

.

This

appliance is equipped with a three-prong [grounding] plug for your

protection against shock hazard and should be plugged directly into a

properly grounded three-prong receptacle. Do not cut or remove the

grounding prong from this plug. For an ungrounded receptacle, an adapter,

which has two prongs and a wire for grounding, can be purchased, plugged

into the ungrounded receptacle and its wire connected to the receptacle

mounting screw. With this wire completing the ground, the appliance cord

plug can be plugged into the adapter and be electrically grounded.

CAUTION: Label all wires prior to disconnection when servicing

controls. Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

Blower Motor

The blower motor does not have oiling holes. Do not attempt to oil the

blower motor.
Blower Wheel

The blower wheel will collect lint and could require periodic cleaning.

If the air output decreases or the noise level increases, it indicates a dirty

blower wheel.
To clean blower wheel:

1. Turn OFF gas supply to the heater.

2. Turn OFF electrical supply to the heater.

3. Remove lower louver from casing assembly (2 screws).

4. Remove reflector from casing assembly (2 screws).

5. Remove upper louver from casing assembly (2 screws).

6. Clean blower wheel with a vacuum cleaner.

7. As parts are being replaced in reverse order, check for gas leaks at all gas

connections before lower louver is replaced onto casing assembly.

WARNING:

Unplugging of blower accessory will not stop the heater from

cycling. To turn off gas to the unvented heater: Push in gas control

knob slightly and turn clockwise to “OFF.” Do not force.

If any of the original wire as supplied with the appliance must be replaced, it must be replaced

with type 125°C wire or its equivalent.

PARTS LIST

INDEX

NO.

PART

NO.

DESCRIPTION

1

R-2396

BLOWER (INCLUDES MOTOR, FAN, AND

FAN HOUSING)

2

R-2503

FAN CONTROL

3

R-2395

WIRE ASSEMBLY

4

8720161

BUSHING - HEYCO #SR5KN4

5

VF-068

CORD SET ASSEMBLY

6

SR-196

BLOWER PAN (SR-18T)

6

SR-198

BLOWER PAN (SR-30T)

7

8520141

RUBBER GROMMET (4 REQUIRED)

8

8520142

BRASS BUSHING (4 REQUIRED)

NOT SHOWN SR-219

HARDWARE PACKAGE

OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (continued)

Advertising