Emerson Process Management 1051 User Manual

Page 20

Advertising
background image

Instruction Manual

D100320X012

1051 and 1052 H & J Actuators

October 2012

20

(key 71), the thrust bearing races (key 72), and the spring seat (key 13) onto the adjustor. Install this assembly into
the spring barrel (key 12). After first cleaning and then coating the set screw (key 75) with thread-locking adhesive
(high strength) (key 77), secure the adjustor with the set screw (key 75).

b. Coat the tapered end of the diaphragm rod (key 10) and the threads of the cap screw (key 9) with lithium grease

(key 76). Bolt the diaphragm plate (key 4) to the diaphragm rod with the cap screw (key 9). Tighten the cap

screw to the torque value listed in table 11.

c. Be certain the travel stops (key 8) are located as shown in figure 11.

d. Install the spring (key 11) into the spring barrel. Install the diaphragm plate and diaphragm rod into the actuator.

Attach the hex nut (key 58), turnbuckle (key 57), hex nut (key 16), and rod end bearing (key 17) to the

diaphragm rod.

e. Install the diaphragm (key 3).

f. Place the upper diaphragm casing (key 1) on the lower diaphragm casing (key 2). If necessary, rotate the lower

bearing seat (key 73) so that the upper diaphragm casing travel stop will not contact the diaphragm when the

casing cap screws (key 5) are tightened. Secure the upper diaphragm casing with the cap screws and hex nuts

(keys 5 and 6) in a criss-cross pattern to the torques shown in table 11. Be sure the warning nameplate is in place

on the casing.

3. If the bearing (key 67) was removed, press in the new bearing. The end of the bearing should be flush with the

outside of the mounting bracket or mounting plate (key 22).

4. For an actuator with an H mounting adaptation, install the output shaft (key 87) through the mounting plate (key

22) and secure it with the retaining ring (key 88). Then, attach the mounting plate and output shaft assembly to the

actuator housing (key 20) with the cap screws (key 23). Tighten the cap screws to the appropriate torque value

listed in table 11.

5. For an actuator with a J mounting adaptation, refer to figures 12 and 13. Install the output shaft (key 87) with

attached coupling (key 90) through the mounting bracket (key 22) and secure it with the retaining ring (key 88).

Attach the mounting bracket and output shaft assembly to the actuator housing (key 20) with the cap screws (key

23). Tighten the cap screws to the appropriate torque value listed in table 11.

6. For an actuator with a J mounting adaptation and a 50.8 mm (2-inch) output shaft, refer to figure 14. Install the

output shaft (key 87) with attached coupling (key 90) through the mounting plate (key 22) and secure it with the

retaining ring (key 88). Attach the mounting plate and output shaft assembly to the actuator housing with the cap

screws (key 23). Tighten the cap screws to the appropriate torque value listed in table 11.

7. Apply lithium grease (key 76) to the output shaft splines. Then, align the lever (key 27) and output shaft so that the

marking that was made in step 6 or 7 of the Disassembly procedure is oriented correctly. Slide the lever into place.

When installing the lever, align the bolt holes in the lever as close as possible with the hole in the rod end bearing

(key 17). Temporarily rotate the lever and output shaft until the rod end bearing no longer interferes with further

installation of the lever. Then, slide the lever as far as it can go onto the output shaft.

8. Clamp the lever to the output shaft with the cap screw (key 28). Tighten the cap screw to the torque value listed in

table 11.

9. For 1052 actuators, complete the Initial Compression portion of the Adjustment section before proceeding.
10. Rotate the lever (key 27) to align with the rod end bearing (key 17). This connection can be aided by stroking the

actuator off its up travel stop with a regulated air source.

Advertising