36

Key 11 Spring

(1)

, steel (for 1052 actuator only)

CASING

PRESSURE

ACTUATOR

SIZE

INITIAL SPRING COMPRESSION

KEY 11

SPRING PART

NUMBER

Push-Down-to-Open

Push-Down-to-Close

Bar

Psig

Bar

Psig

Bar

Psig

0 to 1.2

0 to 18

30

0.2
0.2
0.3

2.7
3.1
4.3

0.2
0.2
0.2

2.7
3.0
3.0

1F361627032

1K509827032

1N751527032

40

0.2
0.3

3.0
4.3

0.2
0.2

3.0
3.0

1L217427042

1P637127082

60

0.3
0.2

3.7
3.5

0.2
0.2

3.0
3.0

1K162727082

1N937327082

0 to 2.3

0 to 33

30

0.3
0.3
0.3
0.2

4.3
3.7
3.9
3.1

0.3
0.2
0.2
0.2

4.2
3.0
3.0
3.0

1N751527032

1F177027092
1F177127092
1F177227092

40

0.3
0.4
0.3

4.3
6.0
4.4

0.3
0.2
0.2

4.3
3.0
3.0

1P637127082

1L217327042

1N844027082

60

0.2
0.5
0.5

3.5
7.0
6.8

0.2
0.2
0.2

3.5
3.0
3.0

1N937327082

1K162827082
1P270227042

70

0.7

10.1

0.2

3.0

1R676027042

0 to 2.8

0 to 40

30

0.3
0.3
- - -

3.7
3.9
- - -

0.3
0.2
0.2

3.7
3.0
3.0

1F177027092
1F171127092
1F177227092

40

0.3
0.4

4.4
6.0

0.2

3.0
3.0

1N844027082

1L217327042

60

0.5
0.5

6.8
7.0

0.2

3.0
3.1

1P270227042

1K16287082

70

0.7

10.1

0.2

3.3

1R676027082

0 to 3.8

0 to 55

30

0.2

3.1

0.2

3.1

1F177227092

40

0.3

4.4

0.2

3.5

1N844027082

70

0.7

10.1

0.7

10.1

1R676027082

0.2 to 1.0

3 to 15

30

- - -

- - -

0.2

3.0

1K509827032

40

- - -

- - -

0.2

3.0

1L217427042

60

0.3

3.7

0.2

3.0

1K16272082

0.2 to 2.1

3 to 30

30

- - -
- - -
- - -
0.3

- - -
- - -
- - -
4.3

0.2
0.2
0.2
0.3

3.1
3.0
3.0
4.2

1F177027092
1F177127092
1F177227092

1N751527032

40

0.3
0.4
- - -

4.3
6.0
- - -

0.3
0.2
0.2

4.3
3.0
3.0

1P637127082

1L217327042

1N844027082

60

0.2
0.5
- - -

3.5
7.0
- - -

0.2
0.2
0.2

3.5
3.0
3.0

1N937327082

1K162827082
1P270227042

70

0.7

10.1

0.2

3.0

1R676027082

1. For more detailed ordering information concerning proper spring selection to obtain the torque required by the valve, consult your Emerson Process Management sales office.