Connecting stacking cables, Connecting stacking cables -7, Fastening the switch to the rack -7 – Enterasys Networks Enterasys SecureStack A2 A2H124-48P User Manual

Page 37: Ба б а

Advertising
background image

Connecting Stacking Cables

SecureStack A2 PoE Installation Guide 3-7

2.

With the mounting brackets attached, position the switch between the vertical frame 
members of the 19‐inch rack as shown in 

Figure 3‐4

. Then fasten the switch securely 

to the frame using four mounting screws (user supplied).

Figure 3-4 Fastening the Switch to the Rack

3.

If you are installing this switch in a stacked configuration, repeat this procedure for 
each switch until all switches have been installed in the stack, then proceed to 

Connecting Stacking Cables

” on page 3‐7. Otherwise, proceed to 

Connecting AC 

and PoE Power

” on page 3‐12.

Connecting Stacking Cables

The stack of switches can be connected in a closed loop or daisy chained. In a closed loop 
all the switches are connected in sequence and the last switch in the stack is connected 
back to the first switch. In the daisy chain configuration the cable that would return the 
connection back to the first switch in a closed loop is not installed. The advantage of the 
closed loop is redundancy, this configuration eliminates any single point of failure. Up to 
eight switches can be stacked together and connected by standard UTP Category 5 or 
better cables. You can add switches and reach up to a maximum of 384 fixed front panel 
ports and 16 SFP ports for a total of 400 Ethernet ports per stack. The stacking cables allow 
the entire stack to operate with a single IP address.

Figure 3‐5

 shows an example of a four‐high stack connected in a closed loop 

configuration. All STACK DOWN and STACK UP connectors are used in the installation. 
The stacking cable connections are from the STACK DOWN connector of one switch to 
the STACK UP connector of the next switch up in the stack. A stacking cable connection 
from the STACK DOWN connector of the switch at the top of the stack to the STACK UP 
connector at the bottom of the stack closes the loop. In a daisy chain topology, one cable 
connection is not made.

1 Rails of 19-inch rack

2 Mounting screws (supplied by user)

Б

А

Б

А

1

2

11

12

13

14

23

24

Console

25

26

27

28

25/Up

26/Down

Stack

27

28

1

3

5

7

9

11 13 15 17 19 21 23

2

4

6

8

10 12 14 16 18 20 22 24

CPU

RPS

MGR

A2H124-24P

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

Advertising