background image

Installing Optional Mini-GBICs

SecureStack A2 PoE Installation Guide 3-31

1.

Remove the protective covers (not shown) from the front panel LC fiber‐optic port 
(port 27 in this example) and from the connectors on each end of the cable.

2.

Insert the LC cable connector into the Mini‐GBIC LC connector until it clicks into 
place.

Figure 3-21 Cable Connection to LC Fiber-Optic Connectors

3.

Plug the other end of the cable into the appropriate port on the other device. Some 
cables may be terminated at the other end with two separate connectors, one for each 
fiber‐optic strand. In this case, ensure that the transmit fiber‐optic strand is connected 
to the receive port and the receive fiber‐optic strand to the transmit port.

Note: Leave the protective covers in place when the connectors are not in use to prevent
contamination.

Note: To remove the LC cable connector, press on its release tab and pull it out of
Mini-GBIC LC connector.

1 Mini-GBIC MT-RJ port connector

3 Release tab

2 LC cable connector

4 Link/Activity LED