XTRA Series • Installation

Installation, cont’d

2-6

XTRA Series • Installation

2-7

Vent Space

Vent Space

Vent Space

Vent Space

Vent Space

Vent Space

Allow sufficient spacing for adequate ventilation

Flexible conduit adapter kit installation

W

The circuit breaker used for this connection should

be rated no lower than 20 amps and no greater than

30 amps.

W

This unit must be installed in accordance with the

National Electrical Code and with all local codes.

An ALL-POLE MAINS SWITCH with a contact

separation of at least 3 mm in each pole shall be

incorporated in the electrical installation of the

building. The installation shall be carried out in

accordance with all applicable installation rules.

W

Installation and service must be performed by a

qualified electrician only.

C

A UL listed electrical distribution box is

recommended for the termination of the conduit

opposite the XPA. See the following "UL
requirements" section.

The optional Flexible Conduit Adapter Kit (Extron part

#70-228-02

) consists of

• One EMT adapter plate
• One 6-foot long electrical conduit
• Three 7.5 feet, 18-gauge spade connector power wires
• One UL rated zip tie wrap
• Three auxiliary crimp style spade connectors designed for

14- to 16-gauge wires

N

If needed, Extron recommends using a UL-rated crimp

tool to terminate the spade connectors. One recommended

choice is the Molex crimp tool (Molex part #19285-0008).

The kit provides a convenient means to replace the XPA's IEC

power cord with conduit, where required by local codes.

C

Make sure that the source device and the XPA are

turned off and disconnected from the power source

before you begin.

U

L requirements

The Underwriters Laboratories (UL) requirements listed below

pertain to the installation of the flexible conduit onto a XPA 1002

or XPA 2001.
• This unit is not to be used beyond its rated voltage range.
• This unit must be wired to a UL listed distribution box.

N

The UL approved electrical distribution box is not included

with either the XPA or the Flexible Conduit Adapter Kit;

the installer is responsible for obtaining and installing the

box.

Installing the flexible conduit kit

Install flexible conduit to the XPA by following the steps below.
1

.

Unplug the IEC power cord from the power amplifier.

2

.

Remove the 8 screws from the top and sides of the XPA

and lift off the cover. See the following illustration.

C

Electrostatic discharge (ESD) can damage IC chips

even though you cannot feel it. You must be

electrically grounded before touching anything inside

the XPA. A grounding wrist strap is recommended.

Advertising
This manual is related to the following products: