Operation, cont’d – Extron electronic XPA 200170V User Manual

Page 15

Advertising
background image

XTRA Series • Operation

Operation, cont’d

3-6

XTRA Series • Operation

3-7

N

On the XPA 2001, the single control adjusts the levels

of both channels simultaneously prior to summing them

together.

To adjust the XPA amplifier's input level, do the following:
1

.

If connecting to a source device with a volume control

(variable output), ensure that the volume on the source

device is set to its lowest point, then adjust the level(s) of

the XPA fully counterclockwise.

2

.

Set the source device's volume to its maximum volume

level. No sound should come out.

3

.

Return to the XPA amplifier and raise the level(s) until

sound distortion occurs, then lower the level(s) slightly

until any distortion disappears. This setting ensures that,

whatever the source device volume setting may be, no

clipping occurs.

N

When setting volume control through a source device,

ensure that the device's volume is set to variable out.

Consult the device's user manual for detailed instructions

on its calibration.

à

Balanced or unbalanced stereo audio input connector — Wire

the 3.5 mm 5-pin captive screw connector for balanced or

unbalanced input.

Unbalanced Stereo Input

Balanced Stereo Input

Do not tin the wires!

Tip

Ring

Tip

Ring

L

R

Sleeves

Tip

Sleeve

Sleeve

Tip

L

R

N

The XPA 1002's output power can be effectively doubled

by using only one input channel and bridging the output.

The XPA 1002 will output 200 watts @ 8 ohms or 120

watts @ 16 ohms in bridged mode.

See "Bridged mono output" in this chapter for wiring

instructions when bridging the XPA 1002.

â

Balanced or unbalanced mono audio input connector — Wire

the 3.5 mm 5-pin captive screw connector for balanced or

unbalanced input.

Balanced Mono Input

Unbalanced Mono Input

(high impedance)

Do not tin the wires!

Tip

Ring

Tip

Ring

L

R

Sleeves

Tip

Sleeve

Sleeve

Tip

L

R

f

Remote control connector — The 3.5 mm 5-pin captive screw

receptacle is used to remotely control two functions through

contact closure: See the following circuit diagram.
• Pins 1, 2, and 3 control volume by varying the DC voltage

from 0 V (full attenuation) to 10 V (maximum volume) with

full muting in effect when pin 2 is connected to ground (pin3).

Use the included 3-pin captive screw connector. See "Remote

volume control" in this chapter.

MUTE

VOLUME

GND

10K OHMS

2K OHMS

MAX

2

VOL/MUTE

3

1

10 V

MIN

1

2 3

STANDBY

MUTE SWITCH

VOL/MUTE

10V

50 mA

Advertising
This manual is related to the following products: