Remote volume control, Bridged mono output, Remote volume control -11 bridged mono output -11 – Extron electronic XPA 200170V User Manual

Page 17: Operation, cont’d

Advertising
background image

XTRA Series • Operation

Operation, cont’d

3-10

XTRA Series • Operation

3-11

Step 1:

Strip and insert the speaker wires into the connector and

tighten the captive screws. Be sure to observe
correct polarity.

Step 2:

Insert the wired connector into the amplifier output

and secure the locking screws on either side.

Do not tin the wires!

OUTPUT

70V

h

High pass filter toggle switch — Use a Tweeker or small

screwdriver to toggle this recessed two-position toggle switch

that alternates between Off and 80 Hz. Setting the switch to

80 Hz prevents the saturation of 70 V/100 V speaker input

transformers by low frequency signals. Saturation may result in

undesired overheating of the speaker transformers.

N

Filtering may be unnecessary if filtering is applied to the

source input signal upstream of the amplifier.

Remote volume control

Options for remote control of the XPA amplifiers include the

Extron VCM 100 and VC 50 volume controllers. Third party 10k

potentiometer volume controllers can also be connected to this

port.
As shown in the following illustration, the XPA's pin 1 is 10

VDC reference voltage. Pin 2 is volume control DC voltage,

range is 0 to 10 V, where 0 V is mute and 10 V provides

maximum volume. Pin 3 is ground.

N

All nominal levels are at ±10%.

VO

L/

M

U

TE

10V

REMOTE

Red

Black

Ground

Extron
STP 22

Cable

VOLUME

VCM 100

MUTE

1

2 3

4 5

STANDBY

VOL/MUTE

10V

50 mA

Pinout diagram for VCM 100 MAAP connection to
XPA's remote connector

Bridged mono output

The power output of the XPA 1002 can be effectively doubled by

bridging the output. Bridging allows power to be output at 200

watts @ 8 ohms or 120 watts @ 16 ohms.

N

The bridging instructions that follow apply only to the

XPA 1002 model.

N

The minimum load impedance when bridging is 8 ohms.

To bridge the output, follow the steps and refer to the diagram

below:
1

.

Unplug the IEC power cord from the power amplifier.

2

.

Wire the output as shown in the following diagram.

Advertising
This manual is related to the following products: