Format

ICE CONTROL SOFTWARE ICS62XX

VIII-22

EPSON

S1C62 FAMILY

DEVELOPMENT TOOL REFERENCE MANUAL

DP

DUMP PROGRAM

#DP,

<address 1>

,

<address 2>

#DP,

<address 1>

#DP

The program area (emulation program memory) from <address 1> to <address 2> is displayed
in hexadecimal format.

(1) When <address 2> defaults, the contents of <address 1> are displayed in a single screen (21

lines, 21

×

8=168 addresses).

(2) When <address 1> and <address 2> default, a single screen is displayed from the previous

address plus one (one more than the previous address).
When DP alone is entered after power on, the data from address 0 are displayed.

(3) When more than one screen of data is displayed, a one line space appears between every

21 lines with about a one second pause.

(4) Hexadecimal and ASCII codes can be displayed together, but the ASCII data operands

are converted by the RETD and LBPX instructions before display.

Example:

Data content 142 ... ASCII display B
(Instruction: RETD 42)

(5) When the last program area passes, the operation terminates.

(6) Commands can be interrupted by input from the "ESC" key.

Program area

(for S1C6S3N7/6S3B7/6S3L7)

000

Address 1

. . . 100

Program data from this area are
displayed.

Address 2

. . . 2FF

3FF

Function