Brksel, Break address mode select – Epson S1C62 Family User Manual

Page 182

Advertising
background image

Format

ICE CONTROL SOFTWARE ICS62XX

VIII-68

EPSON

S1C62 FAMILY

DEVELOPMENT TOOL REFERENCE MANUAL

BRKSEL

BREAK ADDRESS MODE SELECT

#BRKSEL,REM

#BRKSEL,CLR

Function

After setting the break address condition (BA), the program runs until stopped by a break
hit; the settings then remain or clear the previously set BA condition. The clear mode (CLR
mode) is operative at power on. The BA condition remain mode (REM mode) is used when
multiple break conditions are set and the program runs to consecutive break points. The BA
condition clear mode (CLR mode) is used to debug when the break point is changed with
each break.

#BA,0100

#BRKSEL,REM

...

Remain mode is set

#BC
BA 0100
:

#G
*PC=100
*EMULATION END STATUS = BREAK HIT

...

Break is generated when break

*RUN TIME=10mS

condition hits

#BA,200

...

New break condition is set

#BC
BA 0100

...

Pre-break condition remains

BA 0200
:

#BRKSEL,CLR

...

Clear mode is set

#G
*PC=101
*EMULATION END STATUS = BREAK HIT

...

Break condition hits

*RUN TIME=30mS

#BA,300

...

New break condition is set

#BC
BA 0300

...

Pre-break condition is canceled

:

#BA,350,3A0

#BC
BA 0300

...

After break condition remains

BA 0350
BA 03A0

#

Examples

Advertising