ICE CONTROL SOFTWARE ICS62XX

VIII-30

EPSON

S1C62 FAMILY

DEVELOPMENT TOOL REFERENCE MANUAL

HB, HG

HISTORY DATA DISPLAY BACKWARD/FORWARD

#HB

#HG

Indicates the history information before and after the history pointer.

(1) HB: 21 instructions displayed from the current history pointer. The current pointer

decrements 21 after display. (Validated in vicinity of last displayed history value.)

(2) HG: 21 instructions displayed from the current history pointer. The current pointer

increments 21 after display. (Validated from old displayed history value by a screen.)

(3) The current history pointer indicates the last pointer after GO command completion.

Current history pointer = last history pointer - 42

Displayed by HB

21 lines

(Second HB execution)

Current history pointer = last history pointer - 21

Displayed by HB

21 lines

(First HB execution)

Current history pointer = last history pointer
(immediately after GO command)

Function

#BA,108

#G,R
*PC=

*PC=HALT
*EMULATION END STATUS = BREAK HIT
*PC=01E6 A=7 B=6 X=024 Y=026 F=.... SP=4D

*RUN TIME=TIMEOVER

#HB
LOC PC IR OP OPR. A B X Y IDZC MEMORY OPERATION OTHER

2415 0423 83A LD Y,3A 7 6 056 03A 0010
2416 0424 CF1 OR MY,01 7 6 056 03A 0000 R03A=0 W03A=1
2417 0425 FDF RET 7 6 056 03A 0000 R01D=6 R01E=6 R01F=1

: : : : : : : : :
2432 0174 FF8 HALT 7 6 024 026 1000
2433 W01F=1 W01E=7 W01D=5 INT1

2434 INT2
2435* 0108 0E6 JP E6 7 6 024 026 0000

...