Cleaning and Maintenance/Pilot

Oxygen Depletion Sensor Pilot

When the pilot has a large yellow tip flame, clean the Oxygen

Depletion Sensor as follows:
1. Clean the ODS pilot by loosening nut B from the pilot tubing.

When this procedure is required, grasp nut A with an open end

wrench.

2. Blow air pressure through the holes indicated by the arrows.

This will blow out foreign materials such as dust, lint and spider

webs. Tighten nut B also by grasping nut A.

Warning:

Never use needles, wires, or similar cylindrical objects to

clean the pilot to avoid damaging the calibrated ruby that

controls the gas flow.

The (A)VFD26F(M,P)3 gas control maximum and minimum

inputs are listed below.
OFF is the OFF position.
PILOT is the PILOT position.
(A)VFD26F(M,P)3
Max.

20,000 BTU/HR

Min.

14,000 BTU/HR

(A)VFD26FP3L10
Max.

10,000

Min.

N/A

(A)VFD26F(M,P)2 Main Burner Operation

The gas control modulates from a minimum input of 14,000 BTU/

HR ("LO" (1) setting) to a maximum input of 20,000 BTU/HR

("HI" (5) setting).

Figure 20

Cleaning and Maintenance / Main Burner

Warning: Turn off heater and let cool before cleaning.
Caution: You must keep control areas, burner and circulating air

passageways of heater clean. Inspect these areas of heater before

each use. Have heater inspected yearly by a qualified service person.

Heater may need more frequent cleaning due to excessive lint from

carpeting, bedding materials, etc.
Logs

Be careful cleaning and handling logs so as not to damage them.

If logs break or fall apart in handling, spray the broken pieces and

fibers with water, sweep up and discard.

MAIN BURNER AND THERMOSTAT OPERATION