10. VENTING

VENT TERMINATION CLEARANCES

A= Clearance above grade, verandah, porch, deck, or

[balcony (*12 inches (30cm) minimum]

B= Clearance to window or door that may be opened [*12

inches (30cm) minimum]

C= Clearance to permanently closed window [minimum 12

inches (30cm) recommended to prevent condensation on
window]

D= Vertical clearance to ventilated soffit located

above

the terminal within a horizontal distance of 2 feet (60cm)
from the center-line

of the terminal [24 inches ( 60cm)

minimum]

E= Clearance to unventilated soffit [18 inches

(45cm)

minimum]

F= Clearance to outside corner [12 inches minimum]

G= Clearance to inside corner [ 12 inches minimum]

H= *Not to be installed above a meter/regulator assembly

within 3 feet (90cm) horizontally from the center-line of
the regulator

I= Clearance to service regulator vent outlet [*6 feet (1.8m)

minimum]

J= Clearance to non-mechanical air supply inlet to building or

the combustion air inlet to any other appliance [12
inches (30cm) minimum]

K= Clearance to a mechanical air supply inlet [*6

feet

(1.8m) minimum]

L= *** Clearance above paved side-walk or paved driveway

located on public property [*7 feet

(2.1m)

minimum]

M= Clearance under verandah, porch, deck, or balcony [*24

inches (60cm) minimum **]

*** A vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves
both dwellings **
Only permitted if verandah. Porch, deck, or balcony, is fully open on a minimum of 2 sides beneath the floor

As specified in CGA B149 Installation Codes (1991) Note: Local Codes or Regulations may require different clearances