Planning your installation, Simpson duravent parts, Numberdescription number description – Enviro 828 DV.INS. User Manual

Page 13: 908b6" pipe length, black

Advertising
background image

These models have been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE "GS" PIPE FOR GAS
STOVE. Kits are available for vertical venting or horizontal venting. It is recommended that a bead of RTV High Temperature
Silicone be applied to each vent joint before installation.

A MINIMUM VERTICAL LENGTH OF 24" TO THE FIRST 90 DEGREE ELBOW IS REQUIRED. WITH THIS MINIMUM VERTICAL
RISE, HORIZONTAL RUNS OF FROM ONE TO FOUR FEET ARE PERMITTED TO REACH THE OUTSIDE VENT TERMINATION.

VENTING TERMINALS CANNOT BE RECESSED INTO A WALL OR SIDING. FOLLOW THE VENTING SHOWN IN PRECISELY.

These models have been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE "GS" PIPE

FOR GAS STOVES. Kits are available for vertical venting or

horizontal venting. It is recommended that a bead of RTV High Temperature Silicone be applied to each outer

vent joint and milpac to each inner joint before installation.

A MINIMUM VERTICAL LENGTH OF 24" TO THE FIRST 90 DEGREE ELBOW IS REQUIRED. WITH THIS

MINIMUM VERTICAL RISE, HORIZONTAL RUNS OF FROM ONE TO FOUR FEET ARE PERMITTED TO REACH THE

OUTSIDE VENT TERMINATION.

BEFORE BEGINNING THE INSTALLATION TAKE CARE TO ENSURE AN APPROPRIATE OUTSIDE LOCATION FOR

THE VENT TERMINATION CAN BE ACCOMMODATED. FOLLOW THE VENT LENGTH DIAGRAM PRECISELY.

VENTING TERMINALS CANNOT BE RECESSED INTO A WALL OR SIDING.

If extra elbows are being used, overall allowable length will be reduced by 3 ft. per additional elbow

PLANNING YOUR INSTALLATION

There are two basic types of Direct Vent System installations. The two types of installations are:

Simpson Duravent Parts

Number

Description

Number

Description

908B

6" Pipe Length, Black

907B

9" Pipe Length, Black

906 (B)

12" Pipe Length, (Black)

904 (B)

24" Pipe Length, (Black)

903 (B)

36" Pipe Length, (Black)

902 (B)

48" Pipe Length, (Black)

911 (B)

11" to 14-5/8" Pipe , Adjustable, Black

945 (B)

45

° Elbow, (Black)

943S

Flashing, 7/12 to 12/12 Roof Pitch

953 Storm

Collar

990 (B)

90

° Elbow, (Black)

940

Round Support / Wall Thimble Cover

941

Cathedral Ceiling Support Box

943

Flashing, 0/12 to 6/12 Roof Pitch

963 Ceiling

Firestop

988 Wall

Strap

984

Horizontal Square Termination

985

High Wind Horizontal Termination

980 Vertical

Termination

991

High Wind Vertical Termination

950

Vinyl Siding Standoff

942 Wall

Thimble

971

Horizontal Termination Kit A

Add suffix (B) for optional black parts as listed.

Vertical

Termination

Horizontal Termination

13

Advertising