Maintenance, Warning, Intervals – Echo PRO ATTACHMENT SERIES PAS-265 User Manual

Page 16: Aintenance, Skill, Level

Advertising
background image

16

maIntenance

Intervals

m

aIntenance

wArning

Moving parts can amputate fingers or cause severe injuries. Keep hands, clothing and loose objects away from all

openings. Always stop engine, disconnect spark plug, and make sure all moving parts have come to a complete

stop before removing obstructions, clearing debris, or servicing unit. Allow unit to cool before performing service.

Wear gloves to protect hands from sharp edges and hot surfaces.

Your ECHO trimmer is designed to provide many hours of trouble free service. Regular scheduled maintenance will help

your trimmer achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want to take

your unit to an ECHO Service Dealer for maintenance. To help you decide whether you want to DO-IT-YOURSELF

or have the ECHO Dealer do it, each maintenance task has been graded. If the task is not listed see your Echo dealer for

repairs.

skIll

level

Level 1 = Easy to do. Common tools may be required.

Level 2 = Moderate difficulty. Some specialized tools may be required.

ECHO offers REPOWER

TM

Maintenance Kits and Parts to make your maintenance job easier.

COMPONENT / SYSTEM

MAINTENANCE PROCEDURE

REQ'D

SKILL

LEVEL

DAILY OR

BEFORE

USE

EVERY

REFUEL

3 MONTHS

OR 90

HOURS

YEARLY 600

HOURS

Air Filter

Inspect/Clean

1

I / C *

R*

Choke

Inspect/Clean

1

I / C

Fuel Filter

Inspect

1

I *

I / R *

Fuel Cap Gasket

Inspect/Replace

1

I *

R *

Fuel System

Inspect/Replace

1

I (2) *

I (2) *

Spark Plug

Inspect/Clean

1

I / C / R *

Cooling System

Inspect/Clean

2

I / C

Muffler Spark Arrestor

Inspect/Clean/Replace

2

I / C / R *

Cylinder Exhaust Port

Inspect/Clean/Decarbon

2

I / C

Drive Shaft

Grease

2

I (1)

Recoil Starter Rope

Inspect/Clean

1

I / C *

Screws/Nuts/Bolts

Inspect/Tighten/Replace

1

I *

MAINTENANCE PROCEDURE LETTER CODES: I = INSPECT, R = REPLACE, C = CLEAN
IMPORTANT NOTE
- Time intervals shown are maximum. Actual use and your experience will determine the
frequency of required maintenance.
MAINTENANCE PROCEDURE NOTES:
(1) Apply POWER BLENDX

TM

every 25 hours of use.

(2) Low evaporative fuel tanks DO NOT require regular maintenance to maintain emission integrity.
* All recommendations to replace are based on the finding of damage or wear during inspection.

Advertising