MSW 4V SDI rs • Serial Communication

Serial Communication

MSW 4V SDI rs • Serial Communication

3-2

3-3

Using Simple Instruction Set (SIS

TM

) Control

Host-to-switcher communications

The Extron Simple Instruction Set (SIS) commands consist of

one or more characters per field. No special characters are

required to begin or end a command character sequence. When

a command is valid, the switcher executes the command and

sends a response to the host device. All responses from the

switcher to the host end with a carriage return and a line feed

(CR/LF = ]), which signals the end of the response character

string. A string is one or more characters.

Switcher-initiated messages

When a local event, such as a front panel operation or error

condition, occurs, the switcher responds by sending a message

to the host. The switcher-initiated messages are listed below:
(c) Copyright 2006, Extron Electronics, MSW Series Switchers,

Vx.xx]
The switcher issues the copyright message and the input

selected message when it first powers on. Vx.xx is the firmware

version number.
Inn]
The switcher sends the Inn message whenever the selected

input is changed using the front panel buttons. “n” is the input

number.

Error responses

When the switcher receives a valid SIS command, it executes

the command and sends a response to the host device. If

the switcher is unable to execute the command because the

command is invalid or it contains invalid parameters, the

switcher returns an error response to the host. The error

response codes are:
E01 – Invalid input channel number (out of range)
E06 – Invalid input channel change (auto-switch active)
E10 – Invalid command
E13 – Invalid parameter

Timeout

Pauses of 10 seconds or longer between command ASCII

characters result in a timeout. The command operation is

aborted with no other indication.

RS-232 communication

Wire the RS-232 connectors as shown below.

Switcher

PC

Receiv

e

Tr

ansmit Ground

RS-232

Tx Rx

NA

DB9 Pinout (Female)

To control equipment

5

1

9

6

Pin

RS-232

Function

1

2

TX

Transmit data (-)

3

RX

Receive data (+)

4

5

Gnd

Signal ground

6

7

8

9

Figure 3-1 — RS-232 connector wiring

This port has the following RS-232 protocol:
• 9600 baud
• 1 stop bit
• No parity
• 8 data bits